ПОДОГРЕВАЕМЫЙ КИСЛОРОДНЫЙ ДАТЧИК УСТАНОВКА

PROCEDURE


  1. INSTALL HEATED OXYGEN SENSOR


    1. A01UCQHC01
      *a Torque Wrench Fulcrum Length

      Using SST, install the heated oxygen sensor to the front exhaust pipe assembly.

      SST
      09224-00011
      Torque:
      Specified tightening torque
      44 N*m  { 449 kgf*cm, 32 ft.*lbf }

      Note

      If the heated oxygen sensor has been struck or dropped, replace it.

      Tech Tips


      • Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.

        Click here

      • When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 260 mm (10.2 in.)):

        39 N*m (398 kgf*cm, 29 ft.*lbf)

  2. INSTALL FRONT EXHAUST PIPE ASSEMBLY

    Click here

  3. INSPECT FOR EXHAUST GAS LEAK

    Click here