PROCEDURE
INSPECT HOOD SUB-ASSEMBLY
Check that the clearance measurements of areas a through f are within each standard range.
| Area | Measurement | Area | Measurement |
|---|---|---|---|
| a | 1.85 to 5.85 mm (0.0728 to 0.230 in.) | b | -1.85 to 2.15 mm (-0.0728 to 0.0846 in.) |
| c | 3.45 to 7.45 mm (0.136 to 0.293 in.) | d | -2.05 to 1.95 mm (-0.0807 to 0.0768 in.) |
| e | 2.2 to 5.2 mm (0.0866 to 0.205 in.) | f | -1.5 to 1.5 mm (-0.0591 to 0.0591 in.) |