CONDENSER REASSEMBLY

PROCEDURE


  1. INSTALL COOLER DRYER


    1. A01FNG8

      Using pliers, install a new cooler dryer to the modulator.

    2. A01FM9P

      Sufficiently apply compressor oil to 3 new O-rings and the fitting surfaces of a new cap.

      Refrigerant Compressor Oil
      HFC-134a (R134a) ND-OIL 8 or equivalent
      HFO-1234yf (R1234yf) ND-OIL 12 or equivalent

      Note

      Keep the O-rings and O-ring fitting surfaces free from dirt or foreign matter.

    3. A01FOXFC02
      *a Modulator

      Using a 14 mm straight hexagon socket wrench, install the cap to the modulator.

      Torque:
      4.0 N*m  { 41 kgf*cm, 35 in.*lbf }