PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFC-134a(R134a))
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFO-1234yf(R1234yf))
REMOVE INLET NO. 1 AIR CLEANER
REMOVE HOOD LOCK RELEASE LEVER PROTECTOR
DISCONNECT HOOD LOCK CONTROL CABLE ASSEMBLY
REMOVE HOOD LOCK ASSEMBLY
DISCONNECT ENGINE ROOM MAIN WIRE
REMOVE UPPER RADIATOR SUPPORT
DISCONNECT LIQUID PIPE SUB-ASSEMBLY
Remove the bolt.
Remove the bolt and disconnect the liquid pipe sub-assembly from the cooler condenser assembly.
Remove the O-ring from the liquid pipe sub-assembly.
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE
Remove the bolt and disconnect the No. 1 cooler refrigerant discharge hose from the cooler condenser assembly.
Remove the O-ring from the No. 1 cooler refrigerant discharge hose.
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
REMOVE COOLER CONDENSER ASSEMBLY
Disengage the 2 claws.
Disengage the 2 guides and remove the cooler condenser assembly as shown in the illustration.