GENERATOR REMOVAL

PROCEDURE


  1. PRECAUTION

    Note

    After turning the engine switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.

    Click here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. REMOVE V-RIBBED BELT

    Click here

  4. REMOVE GENERATOR ASSEMBLY


    1. B00650KC01
      *1 Engine Wire

      Disengage the clamp.

    2. Remove the bolt and disconnect the engine wire.

    3. B0066OKC01
      *1 Terminal Cap
      *2 Oil Cooler Tube

      Open the terminal cap.

    4. Remove the nut and disconnect the engine wire from terminal B.

    5. Disconnect the generator assembly connector.

    6. Remove the bolt and disconnect the oil cooler tube.

    7. B0067B4C01
      *1 Engine Wire Bracket

      Remove the 2 bolts, 2 nuts and engine wire bracket.

    8. B0066N9

      Using an E8 "TORX" socket wrench, remove the 2 stud bolts and generator assembly.