PROCEDURE
PRECAUTION
Note
After turning the engine switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
REMOVE V-RIBBED BELT
REMOVE GENERATOR ASSEMBLY
| *1 | Engine Wire |
Disengage the clamp.
Remove the bolt and disconnect the engine wire.
| *1 | Terminal Cap |
| *2 | Oil Cooler Tube |
Open the terminal cap.
Remove the nut and disconnect the engine wire from terminal B.
Disconnect the generator assembly connector.
Remove the bolt and disconnect the oil cooler tube.
| *1 | Engine Wire Bracket |
Remove the 2 bolts, 2 nuts and engine wire bracket.
Using an E8 "TORX" socket wrench, remove the 2 stud bolts and generator assembly.