| DTC Code | DTC Name |
|---|---|
| C1ABD | Short to +B in Buzzer |
| C1ABE | Short to GND or Open in Buzzer |
DESCRIPTION
DTC C1ABD is stored when the blind spot monitor sensor RH detects a short to +B in the RCTA buzzer (blind spot monitor buzzer) circuit.
DTC C1ABE is stored when the blind spot monitor sensor RH detects a short to ground or open in the RCTA buzzer (blind spot monitor buzzer) circuit.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| C1ABD | Short to +B in Buzzer |
|
|
| C1ABE | Short to GND or Open in Buzzer |
|
|
CAUTION / NOTICE / HINT
When checking for DTCs, make sure that the blind spot main switch (warning canceling switch assembly) is on.
Inspect the fuses for circuits related to this system before performing the following procedure.
PROCEDURE
CHECK DTC
Clear the DTCs.
Recheck for DTCs and check if the same DTC is output again.
| OK |
|---|
| No DTCs are output. |
| Result | |||
|---|---|---|---|
|
USE SIMULATION METHOD TO CHECKClick here
CHECK HARNESS AND CONNECTOR (RCTA BUZZER - BATTERY AND BLIND SPOT MONITOR SENSOR RH)
Disconnect the U30 RCTA buzzer (blind spot monitor buzzer) connector.
Disconnect the U47 blind spot monitor sensor RH connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
REPLACE RCTA BUZZER (BLIND SPOT MONITOR BUZZER)
Replace the RCTA buzzer (blind spot monitor buzzer).
| Result | ||
|---|---|---|
|
CHECK DTC
Clear the DTCs.
Recheck for DTCs and check if the same DTC is output again.
| OK |
|---|
| No DTCs are output. |
| Result | |||
|---|---|---|---|
|
END
REPLACE BLIND SPOT MONITOR SENSOR RHClick here