Click here

RELAY ON-VEHICLE INSPECTION

Click here
Click here

PROCEDURE


  1. Click here

    INSPECT FAN LH RELAY


    1. A01FMQ6N01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the FAN LH relay.

  2. Click here

    INSPECT FAN RH RELAY


    1. A01FMQ6N01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the FAN RH relay.