PROCEDURE
INSPECT INTAKE SYSTEM
Tech Tips
Perform "Inspection After Repair" after repairing vacuum leaks in the intake system.
w/ Canister Pump Module
w/o Canister Pump Module
Check that there are no vacuum leaks at the points shown in the illustration.
for LHD:
for RHD:
PERFORM INITIALIZATION
Perform "Inspection After Repair" after repairing vacuum leaks in the intake system.
w/ Canister Pump Module
w/o Canister Pump Module
INSPECT INTAKE AIR CONTROL VALVE ACTUATOR
Disconnect the vacuum hose.
| *a | Vacuum applied |
| *b | Vacuum released |
| *c | Valve |
Confirm that the intake air control valve closes smoothly under vacuum and opens smoothly when the vacuum is released.
If the intake air control valve does not close or open smoothly, replace the air cleaner assembly.
Connect the vacuum hose.
INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
Disconnect the No. 1 vacuum switching valve assembly connector.
Disconnect the 2 vacuum hoses from the No. 1 vacuum switching valve assembly.
| *a | Body Ground |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the air cleaner assembly.
Check the operation of the No. 1 vacuum switching valve assembly.
| *a | Filter |
| *b | Port (E) |
| *c | Air |
When vacuum is applied to the port (E), check that air is sucked into the filter.
If air is not sucked into the filter, replace the air cleaner assembly.
| *a | Port (E) |
| *b | Port (F) |
| *c | Air |
Apply battery voltage across the terminals. When vacuum is applied to the port (F), check that air is sucked into the port (E).
If air is not sucked into the port (F), replace the air cleaner assembly.