HEATED OXYGEN SENSOR INSTALLATION

PROCEDURE


  1. INSTALL HEATED OXYGEN SENSOR (for Bank 2)

    Tech Tips

    Perform "Inspection After Repair" after replacing a heated oxygen sensor. (w/ Canister Pump Module)

    Click here


    1. B00679QC01
      *a Torque Wrench Fulcrum Length

      Using SST, install the heated oxygen sensor to the front exhaust pipe assembly.

      SST
      09224-00010
      Torque:
      Specified tightening torque
      44 N*m  { 449 kgf*cm, 32 ft.*lbf }

      Note

      If the heated oxygen sensor has been struck or dropped, replace it.

      Tech Tips


      • Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.

        Click here

      • When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 260 mm (10.2 in.)):

        39 N*m (398 kgf*cm, 29 ft.*lbf)

    2. Engage the heated oxygen sensor grommet to the vehicle body.

    3. Install the bolt.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
  2. INSTALL HEATED OXYGEN SENSOR (for Bank 1)

    Tech Tips

    Perform "Inspection After Repair" after replacing a heated oxygen sensor. (w/ Canister Pump Module)

    Click here


    1. B0065A8C01
      *a Torque Wrench Fulcrum Length

      Using SST, install the heated oxygen sensor to the front exhaust pipe assembly.

      SST
      09224-00010
      Torque:
      Specified tightening torque
      44 N*m  { 449 kgf*cm, 32 ft.*lbf }

      Note

      If the heated oxygen sensor has been struck or dropped, replace it.

      Tech Tips


      • Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.

        Click here

      • When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 260 mm (10.2 in.)):

        39 N*m (398 kgf*cm, 29 ft.*lbf)

    2. Engage the heated oxygen sensor grommet to the vehicle body.

  3. CONNECT HEATED OXYGEN SENSOR CONNECTOR


    1. for Bank 2:


      1. Engage the clamp.

      2. Connect the heated oxygen sensor connector.

      3. Install the floor carpet to the original position.

    2. for Bank 1:


      1. Engage the clamp.

      2. Connect the heated oxygen sensor connector.

      3. Install the floor carpet to the original position.

  4. INSTALL CONSOLE BOX ASSEMBLY

    Click here

  5. INSPECT FOR EXHAUST GAS LEAK

    Click here

  6. PERFORM INITIALIZATION (w/ Canister Pump Module)


    1. Perform "Inspection After Repair" after replacing a heated oxygen sensor.

      Click here