REFRIGERANT LINE REMOVAL

PROCEDURE


  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM

    for HFC-134a (R134a):

    Click here

    for HFO-1234yf (R1234yf):

    Click here

  2. REMOVE PIPING CLAMP (for Suction Hose Sub-assembly)


    1. While pressing the end of the suction hose sub-assembly into the end of the suction pipe sub-assembly, use pliers to squeeze together both sides of the piping clamp until it breaks apart.

      A01RKIVC02
      *1 Suction Pipe Sub-assembly *2 Suction Hose Sub-assembly
      *3 Piping Clamp - -
      *a Press In - -

      Note


      • If any foreign matter is adhered to the connecting part, brush it off or use compressed air to remove it.

      • Make sure that fragments of the piping clamp do not enter the piping.

    2. Disconnect the suction hose sub-assembly.

      Note

      Clean off any foreign matter near the ends of the suction hose sub-assembly and suction pipe sub-assembly.

    3. Remove the 2 O-rings from the suction hose sub-assembly.

      Note

      Wrap the open ends of the separated suction pipe sub-assembly and suction hose sub-assembly with vinyl tape to prevent entry of moisture and foreign matter.

    4. Remove the piping clamp.

  3. REMOVE PIPING CLAMP (for Air Conditioner Tube and Accessory Assembly)

    Click here