BLOWER UNIT REASSEMBLY

PROCEDURE


  1. INSTALL NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY


    1. A01RLT9C01
      *a Link

      Connect the 2 links of the blower assembly to the 2 plates of the No. 1 blower damper servo sub-assembly as shown in the illustration.

    2. Install the No. 1 blower damper servo sub-assembly with the 2 screws.

  2. INSTALL BLOWER MOTOR WITH FAN SUB-ASSEMBLY


    1. A01RHJO

      Install the blower motor with fan sub-assembly with the 3 screws.

      Note

      Replace the blower motor with fan sub-assembly if it has been dropped or subjected to a severe impact.

  3. INSTALL CLEAN AIR FILTER


    1. Engage the 2 guides on the cutout side of the cooling unit parts and then engage the 2 guides as shown in the illustration to install the clean air filter.

      A01VC72C04
      *a Cutout *b Rib
      B004PI4 Install in this Direction (1) B004OIV Install in this Direction (2)

      Note


      • Make sure that the "UP" marks are facing the correct direction before installing the clean air filter.

      • Make sure that there is no clearance between the clean air filter and cooling unit parts and that the clean air filter is not deformed.

    2. A01RK4HC01
      B004PI4 Install in this Direction

      Install the air filter sub-assembly as shown in the illustration.

      Note

      Make sure that the "UP" mark is facing the correct direction before installing the air filter sub-assembly.

  4. INSTALL AIR FILTER COVER PLATE


    1. A01RJVBC01
      B004PI4 Install in this Direction (1)
      B004OIV Install in this Direction (2)

      Engage the 2 guides and claw as indicated by the arrows, in the order shown in the illustration to install the air filter cover plate.