COMBINATION METER DISASSEMBLY

PROCEDURE


  1. REMOVE COMBINATION METER GLASS


    1. A01RHH4

      Remove the 9 bushes.

    2. A01RKA0

      Disengage the 12 claws to remove the combination meter glass.

  2. REMOVE NO. 1 COMBINATION METER COVER


    1. A01RI0P

      Remove the 2 screws.

    2. Disengage the 10 claws to remove the No. 1 combination meter cover.

  3. REMOVE NO. 1 COMBINATION METER PLATE


    1. A01RIOCC01

      Disengage the 3 guides and remove the No. 1 combination meter plate.

  4. REMOVE NO. 2 COMBINATION METER CASE


    1. A01RH99

      Remove the screw.

    2. A01RK02

      Disengage the 2 guides and remove the No. 2 combination meter case.

    3. A01RKZU

      Remove the 2 screws.

    4. A01RL9DC01
      B004PI4 Remove in this Direction

      Disengage the 2 guides and disconnect the connector to remove the No. 2 combination meter case with combination meter multi-display as shown in the illustration.

      Note


      • Make sure to pull the connector straight up when disconnecting it as it is easily damaged.

      • Do not apply excessive force to the connector.

    5. A01RKY5C01
      B004PI4 Remove in this Direction

      Disengage the 2 guides to remove the combination meter multi-display from the No. 2 combination meter case as shown in the illustration.

  5. REMOVE NO. 2 METER CIRCUIT PLATE


    1. A01RJJL

      Remove the 4 screws.

    2. A01RHC6C01
      B004PI4 Remove in this Direction

      Disengage the 4 guides to remove the No. 2 meter circuit plate as shown in the illustration.

  6. REMOVE METER CIRCUIT PLATE


    1. A01RL59

      Disengage the 4 claws and 4 guides.

    2. A01RIO2C01
      B004PI4 Remove in this Direction

      Disengage the 4 claws and raise the 2 holders.

      Note

      Make sure not to rotate the holder 90° or more, or it may be damaged.

    3. Disconnect each connector to remove the TFT display from the meter circuit plate as shown in the illustration.