COMBINATION METER REMOVAL

CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during combination meter assembly removal/installation are shown below.

Necessary Procedure After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedure Effect/Inoperative Function when Necessary Procedure not Performed Link
Disconnect cable from negative auxiliary battery terminal Memorize steering angle neutral point Lane departure alert system (w/ Steering Control)

Click here

Intelligent clearance sonar system*1
Simple intelligent parking assist system*1
Pre-crash safety system
Parking assist monitor system

Click here

Initialize back door lock Power door lock control system

Click here

*1: When performing learning using the GTS.

Click here

PROCEDURE


  1. PRECAUTION

    Note

    After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

    Click here

  2. DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. DISCONNECT FRONT DOOR OPENING TRIM WEATHERSTRIP LH

    Click here

  4. REMOVE FRONT PILLAR GARNISH LH

    Click here

  5. REMOVE NO. 1 INSTRUMENT PANEL SPEAKER PANEL SUB-ASSEMBLY

    Click here

  6. DISCONNECT FRONT DOOR OPENING TRIM WEATHERSTRIP RH

    Click here

  7. REMOVE FRONT PILLAR GARNISH RH

    Tech Tips

    Use the same procedure as for the LH side.

  8. REMOVE NO. 2 INSTRUMENT PANEL SPEAKER PANEL SUB-ASSEMBLY

    Click here

  9. REMOVE INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY


    1. Apply protective tape to the areas shown in the illustration.

      B004PZMC01
      B004PFI Protective Tape - -
    2. Remove the 2 clips.

      B004PCQ
    3. Disengage the 11 clips and 4 guides as shown in the illustration.

      B004QH6C01
      B004PI4 Remove in this Direction - -

      Note


      • Do not damage the upper instrument panel assembly.

      • Do not allow the wire harnesses to interfere with the surrounding parts.

    4. Lift the upper instrument panel assembly as shown in the illustration.

      B004OWE

      Note


      • Do not damage the upper instrument panel assembly.

      • Do not allow the wire harnesses to interfere with the surrounding parts.

    5. Using a moulding remover, slightly lift the instrument cluster finish panel assembly and then disengage the 17 clips and 10 guides as shown in the illustration to remove the instrument cluster finish panel assembly.

      B004PONC01
      B004QOG Insert Moulding Remover Here B004PI4 Remove in this Direction
      B004PRK Order of Removal - -
  10. REMOVE COMBINATION METER ASSEMBLY


    1. B004PIC

      Remove the 4 screws.

    2. B004QTJ

      Disengage the clamp.

    3. Disconnect the 2 connectors to remove the combination meter assembly.