ELECTRONICALLY CONTROLLED BRAKE SYSTEM FREEZE FRAME DATA


  1. FREEZE FRAME DATA/INFORMATION


    1. Using the GTS, check the vehicle condition (ECU, sensor) when the brake system operates or a DTC is output.

    2. The Freeze Frame Data that is recorded when a DTC is stored can be used to check the INF codes, but only for DTCs which can be stored.

  2. CHECK FREEZE FRAME DATA WHEN BRAKE SYSTEM OPERATES


    1. Freeze Frame Data is stored when the brake system operates. The Freeze Frame Data is updated each time the system operates.

    2. Once Freeze Frame Data is stored when the system operates, it is not cleared until the DTC is cleared.

    3. The number of times (maximum: 31) the power switch has been turned from off to on (IG) since the last time the system was activated can be stored and displayed.

      Tech Tips


      • When the vehicle is stopped (vehicle speed below 7 km/h (4 mph)), turning the power switch from off to on (IG) does not cause the value to increase.

      • The value "31" is displayed when the power switch was turned on (IG) more than 31 times.

    4. Check Freeze Frame Data when the system operates.


      1. Turn the power switch off.

      2. Connect the GTS to the DLC3 and turn the power switch on (IG).

      3. Enter the following menus: Chassis / ABS/VSC/TRC / Utility.

      4. Select "ABS History".


        Chassis > ABS/VSC/TRC > Utility
        Tester Display
        ABS History
      5. Check the Freeze Frame Data when the system operates.

  3. CHECK FREEZE FRAME DATA AND INFORMATION WHEN DTC WAS STORED


    1. Freeze Frame Data is stored when a DTC is output.

    2. Once Freeze Frame Data is stored when a DTC is output, it is not updated or cleared until the DTC is cleared.

    3. The number of times (maximum: 31) the power switch has been turned from off to on (IG) since a DTC was output can be stored and displayed.

      Tech Tips

      The value "31" is displayed when the power switch was turned on (IG) more than 31 times.

    4. Check the Freeze Frame Data and INF code when a DTC is output.


      1. Turn the power switch off.

      2. Connect the GTS to the DLC3 and turn the power switch on (IG).

      3. Enter the following menus: Chassis / ABS/VSC/TRC / Trouble Codes.


        Chassis > ABS/VSC/TRC > Trouble Codes
      4. Select a DTC to display the Freeze Frame Data.

      5. Check the Freeze Frame Data for the output DTC.

        Tech Tips

        If an "INF Code" item appears when the Freeze Frame Data is displayed, select and check the INF code.


        Chassis > ABS/VSC/TRC
        Tester Display Measurement Item Range Normal Condition Diagnostic Note
        FR Speed Open Front speed sensor RH open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        FL Speed Open Front speed sensor LH open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        RR Speed Open Rear speed sensor RH open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        RL Speed Open Rear speed sensor LH open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        Yaw Rate Open Yaw rate sensor open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        Deceleration Open Acceleration sensor open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        Steering Open Steering angle sensor open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        Stroke Open Brake pedal stroke sensor assembly open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        Stroke2 Open Brake pedal stroke sensor assembly 2 open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        Accumulator Open Accumulator pressure sensor open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        HV Communication Open Hybrid vehicle communication open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        FR Speed Sensor Voltage Open Front speed sensor RH voltage open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        FL Speed Sensor Voltage Open Front speed sensor LH voltage open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        RR Speed Sensor Voltage Open Rear speed sensor RH voltage open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        RL Speed Sensor Voltage Open Rear speed sensor LH voltage open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        Yaw Rate Sensor Voltage Open Yaw rate sensor voltage open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        Detailed Freeze DTC Information code (INF Code) for DTC Min.: 0, Max.: 65535 - Information code (INF Code) of DTC is displayed
        Number of IG ON Number of times power switch turned on (IG) after Freeze Frame Data stored 0 to 31 - -
        Buzzer Meter buzzer ON or OFF

        ON: Buzzer on

        OFF: Buzzer off

        -
        Stop Light SW Stop light switch assembly ON or OFF

        ON: Brake pedal depressed

        OFF: Brake pedal released

        -
        Parking Brake SW Parking brake switch assembly ON or OFF

        ON: Parking brake applied

        OFF: Parking brake released

        -
        TRC(TRAC)/VSC OFF SW VSC OFF switch (Combination switch assembly) ON or OFF

        ON: Switch on

        OFF: Switch off

        -
        Reservoir Warning SW Brake fluid level warning switch ON or OFF

        ON: Reservoir level low

        OFF: Reservoir level normal

        -
        Shift Lever Position Shift position information Fail, 1st, 2nd, 3rd, 4th, 5th, 6th/B, D/M, P,N or R Actual shift position -
        Operated System Operated system status ABS, VSC, TRC, BA, PB, PBA, HAB, HA-CTRL, TSC, Fail, Non or Sys -

        ABS: ABS activated

        VSC: VSC activated

        TRC: TRC activated

        BA: BA activated

        PB: PB activated

        PBA: PBA activated

        HAB: High power assist brake activated*

        HA-CTRL: Hill-start assist control activated

        TSC: Trailer sway control activated*

        Fail: Fail-safe mode activated

        Non: No system activated

        Sys: System prohibited

        Tech Tips

        *: Not supported

        Stroke Sensor Brake pedal stroke sensor assembly Min.: 0.00 V, Max.: 5.00 V Brake pedal released: 0.65 to 1.35 V Reading increases when brake pedal is depressed
        Stroke Sensor Grade Brake pedal stroke sensor assembly change Min.: -2560 mm/s, Max.: 2540 mm/s Brake pedal released or depressed and held: 0 mm/s Brake pedal is being moved: Changes in proportion to the operation speed of the brake pedal
        Stroke Sensor2 Brake pedal stroke sensor assembly 2 Min.: 0.00 V, Max.: 5.00 V Brake pedal released: 3.65 to 4.35 V Reading decreases when brake pedal is depressed
        Yaw Rate Sensor Yaw rate sensor Min.: -128 degrees/s, Max.: 127 degrees/s

        Vehicle stopped: 0 degrees/s

        Turning right: -128 to 0 degrees/s

        Turning left: 0 to 127 degrees/s

        -
        Lateral G Lateral G

        Min.: -25.10 m/s2, Max.: 24.90 m/s2

        - During turning: Changes in proportion with lateral acceleration
        Forward and Rearward G Forward and backward G

        Min.: -25.10 m/s2, Max.: 24.90 m/s2

        - During acceleration/deceleration: Changes in proportion with acceleration
        FR Wheel Speed Front speed sensor RH Min.: 0 km/h (0 mph), Max.: 326.4 km/h (203 mph) Vehicle stopped: 0 km/h (0 mph) When driving at constant speed: No large fluctuations
        FL Wheel Speed Front speed sensor LH Min.: 0 km/h (0 mph), Max.: 326.4 km/h (203 mph) Vehicle stopped: 0 km/h (0 mph) When driving at constant speed: No large fluctuations
        RR Wheel Speed Rear speed sensor RH Min.: 0 km/h (0 mph), Max.: 326.4 km/h (203 mph) Vehicle stopped: 0 km/h (0 mph) When driving at constant speed: No large fluctuations
        RL Wheel Speed Rear speed sensor LH Min.: 0 km/h (0 mph), Max.: 326.4 km/h (203 mph) Vehicle stopped: 0 km/h (0 mph) When driving at constant speed: No large fluctuations
        Vehicle Speed Maximum wheel speed sensor Min.: 0 km/h (0 mph), Max.: 326.4 km/h (203 mph) Vehicle stopped: 0 km/h (0 mph) When driving at constant speed: No large fluctuations
        Vehicle Speed Grade Vehicle acceleration

        Min.: -25.10 m/s2, Max.: 24.90 m/s2

        Vehicle stopped: 0 m/s2

        During driving: Changes in proportion with vehicle acceleration/deceleration
        Accelerator Opening Angle % Percentage of accelerator pedal opening angle Min.: 0.0%, Max.: 127.5% Accelerator pedal released: 0.0% During accelerator pedal operation: Changes in proportion with the pedal movement
        ECB Motor Relay Motor relay 1 operation request ON or OFF

        ON: Relay on

        OFF: Relay off

        ECB: Electronically Controlled Brake System
        ECB Motor Relay2 Motor relay 2 operation request ON or OFF

        ON: Relay on

        OFF: Relay off

        ECB: Electronically Controlled Brake System
        ECB Main Relay Main relay operation request ON or OFF

        ON: Relay on

        OFF: Relay off

        ECB: Electronically Controlled Brake System
        IG1 Voltage Value IG1 voltage value Min.: 0.00 V, Max.: 20.00 V - Changes in proportion to auxiliary battery voltage
        IG2 Voltage Value IG2 voltage value Min.: 0.00 V, Max.: 20.00 V - Changes in proportion to auxiliary battery voltage
        BS1 Voltage Value BS1 voltage value Min.: 0.00 V, Max.: 20.00 V - Changes in proportion to auxiliary battery voltage
        BS2 Voltage Value BS2 voltage value Min.: 0.00 V, Max.: 20.00 V - Changes in proportion to auxiliary battery voltage
        VM1 Voltage Value VM1 voltage value Min.: 0.00 V, Max.: 20.00 V - Changes in proportion to auxiliary battery voltage
        VM2 Voltage Value VM2 voltage value Min.: 0.00 V, Max.: 20.00 V - Changes in proportion to auxiliary battery voltage
        Motor Relay Voltage Value Motor relay voltage value Min.: 0.00 V, Max.: 20.00 V - -
        FR Target Oil Pressure Front wheel RH target oil pressure Min.: 0.00 MPa, Max.: 20.00 MPa - Different according to target oil pressure of each wheel
        FL Target Oil Pressure Front wheel LH target oil pressure Min.: 0.00 MPa, Max.: 20.00 MPa - Different according to target oil pressure of each wheel
        RR Target Oil Pressure Rear wheel RH target oil pressure Min.: 0.00 MPa, Max.: 20.00 MPa - Different according to target oil pressure of each wheel
        RL Target Oil Pressure Rear wheel LH target oil pressure Min.: 0.00 MPa, Max.: 20.00 MPa - Different according to target oil pressure of each wheel
        Inspection Mode Inspection mode Other or Inspect

        Other: Normal mode

        Inspect: Inspection mode

        -
        Steering Angle Sensor Steering angle sensor Min.: - 3276.8 degrees, Max.: 3276.7 degrees

        Turning left: Increases

        Turning right: Decreases

        -
        VCM1 Voltage Value VCM1 voltage value Min.: 0.00 V, Max.: 10.00 V 6.29 to 7.64 V -
        VCM2 Voltage Value VCM2 voltage value Min.: 0.00 V, Max.: 10.00 V 6.29 to 7.64 V -
        TRC/VSC Off Mode TRC/VSC off mode Normal, TRC OFF, VSC Expert Mode or VSC OFF

        Normal: Normal mode

        TRC OFF: TRC off mode

        VSC Expert Mode: VSC expert mode

        VSC OFF: VSC off mode

        -
        Regulator Pressure Sensor Output Variant Reaction force pressure sensor output variant Min.: -30 MPa/s, Max.: 225 MPa/s - -
        SLA Solenoid Current Linear solenoid additional valve (SLA) current Min.: 0.00 A, Max.: 1.50 A Brake pedal released: 0.00 A -
        SLR Solenoid Current Linear solenoid reduction valve (SLR) current Min.: 0.00 A, Max.: 1.50 A Brake pedal released: 0.00 A -
        Target Oil Pressure Wheel target hydraulic pressure Min.: 0.00 MPa, Max.: 20.00 MPa - Changes according to the target wheel cylinder hydraulic pressure
        Voltage of Stroke Sensor Voltage of brake pedal stroke sensor assembly Min.: -2.50 V, Max.: 2.49 V - -
        Voltage of Stroke Sensor2 Voltage of brake pedal stroke sensor assembly 2 Min.: -2.50 V, Max.: 2.49 V - -
        IG Switch Power switch on (IG) status ON or OFF - -
        Elapsed Time after Freeze Trigger Elapsed time after storing Freeze Frame Data Min.: 0 msec, Max.: 1020 msec - -
        Reaction Force Pressure Pressure value of stroke simulator Min.: 0.00 MPa, Max.: 24.48 MPa 0.00 to 21.60 MPa

        Brake pedal is being depressed: Changes in proportion to the depression force of the brake pedal

        Brake pedal released: 0.00 MPa

        Servo Pressure Pressure value of servo Min.: 0.00 MPa, Max.: 24.48 MPa 0.00 to 21.60 MPa

        Brake pedal is being depressed: Changes in proportion to the depression force of the brake pedal

        Brake pedal released: 0.00 to 2.10 MPa

        Reaction Force Pressure Sensor Temperature Reaction force pressure sensor temperature Min.: -80°C (-112°F), Max.: 175°C (347°F) -30°C (-22°F) to 100°C (212°F) -
        Servo Pressure Sensor Temperature Servo pressure sensor temperature Min.: -80°C (-112°F), Max.: 175°C (347°F) -30°C (-22°F) to 100°C (212°F) -
        Accumulator Pressure Sensor Temperature Accumulator pressure sensor temperature Min.: -80°C (-112°F), Max.: 175°C (347°F) -30°C (-22°F) to 100°C (212°F) -
        Accumulator Pressure Accumulator pressure output value Min.: 0.00 MPa, Max.: 24.48 MPa 0.00 to 21.60 MPa When brake fluid is stored in the accumulator: Accumulator pressure changes in accordance with volume of fluid stored in the accumulator
        MT Voltage Value (ABS) ABS motor voltage value Min.: 0.00 V, Max.: 20.00 V

        ABS motor off: 0.00 V

        ABS motor on: 11.00 to 14.00 V

        -
        VCSK Voltage Value VCSK voltage value Min.: 0.000 V, Max.: 5.500 V 4.800 to 5.200 V -
        ECB Solenoid (SGH) Switching solenoid valve (SGH) ON or OFF

        ON: Solenoid on

        OFF: Solenoid off

        ECB: Electronically Controlled Brake System
        ECB Solenoid (SSA) Switching solenoid valve (SSA) ON or OFF

        ON: Solenoid on

        OFF: Solenoid off

        ECB: Electronically Controlled Brake System
        Reaction Force Pressure Sensor Open Reaction force pressure sensor open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
        Servo Pressure Sensor Open Servo pressure sensor open detection Error or Normal

        Error: Momentary interruption

        Normal: Normal

        -
  4. CLEAR FREEZE FRAME DATA AND INFORMATION

    Note

    Clearing the DTCs will also clear the Freeze Frame Data and information codes (INF codes).


    1. Turn the power switch off.

    2. Connect the GTS to the DLC3.

    3. Turn the power switch on (IG).

    4. Turn the GTS on.

    5. Clear the DTCs and Freeze Frame Data.

      Click here


      Chassis > ABS/VSC/TRC > Clear DTCs