PROCEDURE
INSPECT WATER INLET WITH THERMOSTAT SUB-ASSEMBLY
Immerse the water inlet with thermostat sub-assembly in water and then gradually heat the water.
Check that the valve of the water inlet with thermostat sub-assembly opens at the specified temperature.
| Standard Valve Opening Temperature | |||
|---|---|---|---|
|
If the result is not as specified, replace the water inlet with thermostat sub-assembly.
| *A | Compression Spring Shape: Tapered |
| *B | Compression Spring Shape: Straight |
| *a | Valve Lift |
| *b | Compression Spring |
Check the valve lift.
| Standard Valve Lift | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the water inlet with thermostat sub-assembly.
Check that the valve is fully closed when the water inlet with thermostat sub-assembly is at low temperatures (below 77°C (171°F)).
If it is not fully closed, replace the water inlet with thermostat sub-assembly.