HV RELAY ASSEMBLY INSPECTION

PROCEDURE


  1. INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY


    1. Inspect SMRB:


      1. Measure the resistance according to the value(s) in the table below.

        B004PMLC24
        *a

        Component without harness connected

        (HV Battery Junction Block Assembly)

        - -
        Standard Resistance
        Tester Connection Condition Specified Condition
        S4-1 (CBI) - A-1 (+) Auxiliary battery voltage not applied between terminals M37-1 (SMRB) and M37-3 (GND) 10 kΩ or higher
        S4-1 (CBI) - A-1 (+) Auxiliary battery voltage applied between terminals M37-1 (SMRB) and M37-3 (GND) Below 1 Ω
      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        M37-1 (SMRB) - M37-3 (GND) -40 to 80°C (-40 to 176°F) 20.6 to 40.8 Ω

        If the result is not as specified, replace the HV battery junction block assembly.

    2. Inspect SMRG:


      1. Measure the resistance according to the value(s) in the table below.

        B004PMLC41
        *a

        Component without harness connected

        (HV Battery Junction Block Assembly)

        - -
        Standard Resistance
        Tester Connection Condition Specified Condition
        S3-1 (CEI) - z12-1 (-) Auxiliary battery voltage not applied between terminals M37-4 (SMRG) and M37-3 (GND) 10 kΩ or higher
        S3-1 (CEI) - z12-1 (-) Auxiliary battery voltage applied between terminals M37-4 (SMRG) and M37-3 (GND) Below 1 Ω
      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        M37-4 (SMRG) - M37-3 (GND) -40 to 80°C (-40 to 176°F) 20.6 to 40.8 Ω

        If the result is not as specified, replace the HV battery junction block assembly.

    3. Inspect SMRP:


      1. Measure the resistance according to the value(s) in the table below.

        B004PMLC42
        *a

        Component without harness connected

        (HV Battery Junction Block Assembly)

        - -
        Standard Resistance
        Tester Connection Condition Specified Condition
        S3-1 (CEI) - z12-1 (-) Auxiliary battery voltage not applied between terminals M37-2 (SMRP) and M37-3 (GND) 10 kΩ or higher
        S3-1 (CEI) - z12-1 (-) Auxiliary battery voltage applied between terminals M37-2 (SMRP) and M37-3 (GND) 24.3 to 29.7 Ω
      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        M37-2 (SMRP) - M37-3 (GND) -40 to 80°C (-40 to 176°F) 140 to 290 Ω

        If the result is not as specified, replace the HV battery junction block assembly.