FRAME WIRE INSTALLATION

PROCEDURE


  1. INSTALL HV FLOOR UNDER WIRE

    CAUTION:

    Wear insulated gloves.


    1. B004PHCC03
      *A for LHD
      *B for RHD

      Engage the clamp (B).

    2. Install a new clamp (A).

    3. B004OVW

      Insert the HV floor under wire into the floor panel hole and engage the grommet.

    4. Install 3 new clamps in the order shown in the illustration.

      A01RJZUN02
    5. B004OPT

      Install the HV floor under wire with the 2 nuts.

      Torque:
      8.5 N*m  { 87 kgf*cm, 75 in.*lbf }
  2. CONNECT NO. 2 PARKING BRAKE CABLE ASSEMBLY


    1. Connect the No. 2 parking brake cable assembly with the 2 bolts.

      Torque:
      6.0 N*m  { 61 kgf*cm, 53 in.*lbf }
  3. INSTALL FRONT SUSPENSION CROSSMEMBER SUB-ASSEMBLY

    Click here

  4. INSTALL FRONT FLOOR COVER RH

    Tech Tips

    Perform the same procedure as for the front floor cover LH.

    Click here

  5. INSTALL NO. 1 FLOOR UNDER COVER ASSEMBLY

    Click here

  6. CONNECT HV FLOOR UNDER WIRE

    CAUTION:

    Wear insulated gloves.


    1. Connect the shield ground to the HV battery.

    2. Connect the 2 HV battery junction block assembly connectors.

      Note

      Make sure that the connectors are connected securely.

  7. INSTALL NO. 1 HV BATTERY COVER PANEL RH

    Click here

  8. INSTALL REAR SEAT CUSHION LEG SUB-ASSEMBLY

    Click here

  9. INSTALL REAR UNDER COVER

    Click here

  10. INSTALL REAR UNDER SIDE COVER LH

    Click here

  11. INSTALL REAR DOOR SCUFF PLATE LH

    Click here

  12. INSTALL REAR UNDER SIDE COVER RH

    Tech Tips

    Use the same procedure as for the LH side.

    Click here

  13. INSTALL REAR DOOR SCUFF PLATE RH

    Tech Tips

    Use the same procedure as for the LH side.

    Click here

  14. INSTALL REAR SEAT CUSHION LOCK HOOK

    Click here

  15. INSTALL REAR SEAT CUSHION ASSEMBLY

    Click here

  16. CONNECT HV FLOOR UNDER WIRE

    Click here

  17. CONNECT ENGINE WIRE

    CAUTION:

    Wear insulated gloves.

    Note

    Do not allow any foreign matter or water to enter the inverter with converter assembly.


    1. Engage the 2 clamps and connect the engine wire.

    2. Install the bolt.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    3. A01VCQG

      Connect the 2 inverter with converter assembly connectors and move each lock lever as shown in the illustration.

      Note


      • To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.

      • Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connectors.

      • Do not touch the waterproof seal or terminals of the connector.

  18. INSTALL NO. 1 ENGINE COVER SUB-ASSEMBLY

    Click here

  19. INSTALL OUTER COWL TOP PANEL SUB-ASSEMBLY

    Click here

  20. INSTALL COWL BODY MOUNTING REINFORCEMENT LH

    Click here

  21. INSTALL WATER GUARD PLATE LH

    Click here

  22. INSTALL NO. 1 HEATER AIR DUCT SPLASH SHIELD SEAL (for LHD)

    Click here

  23. INSTALL NO. 2 HEATER AIR DUCT SPLASH SHIELD SEAL (for RHD)

    Click here

  24. INSTALL WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY

    Click here

  25. INSTALL SERVICE PLUG GRIP

    Click here