DESCRIPTION
The hybrid vehicle control ECU has a self-diagnosis system. If the computer, hybrid control system, or a component is not working properly, the ECU records the conditions that relate to the fault. The ECU also illuminates the master warning light in the combination meter assembly and provides other appropriate messages on the multi-information display, such as the HV system warning message, HV battery warning message, or discharge warning message.
| *A | for LHD | *B | for RHD |
| *a | MIL | *b | Charge Warning Light |
| *c | READY Light | *d | Master Warning Light |
| *e | Multi-information Display | - | - |
Tech Tips
The master warning light will illuminate when the hybrid control system is malfunctioning and the light will blink when in inspection mode.
2 TRIP DETECTION LOGIC
Following is the description for storage of DTC using "2 trip detection logic".
When a malfunction is first detected, the malfunction is temporarily stored in the hybrid vehicle control ECU memory (1st trip). If the same malfunction is detected during the next drive cycle, the MIL is illuminated (2nd trip).
FREEZE FRAME DATA
The hybrid vehicle control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was moving or stationary, whether the engine was warmed up or not, as well as other data recorded at the time of a malfunction.
AUXILIARY BATTERY VOLTAGE
If voltage is below 11 V, recharge or replace the auxiliary battery.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
MIL (Malfunction Indicator Lamp)
The MIL is illuminated when the power switch is first turned on (IG), before the READY light comes on.
When the READY indicator turns on, the MIL should turn off. If the MIL remains illuminated, the diagnosis system has detected a malfunction or abnormality in the system.
Tech Tips
If the MIL is not illuminated when the power switch is first turned on (IG), check the MIL circuit.
for SFI System: Click here
RELEVANT SYSTEMS CHECK
The inspection areas and outline of the inspection for each circuit are listed below.
| System to be Inspected | Malfunction Possibility | Inspection Content |
|---|---|---|
| Motor Resolver Circuit | Motor resolver signal |
|
| Motor High-voltage Circuit | Motor (MG2) output |
|
| Generator Resolver Circuit | Generator resolver signal |
|
| Generator High-voltage Circuit | Generator (MG1) output |
|
| Inverter Low-voltage Circuit | Power supply voltage from +B or communication between hybrid vehicle control ECU and motor generator control ECU |
|
| HV Battery High-voltage Line Circuit | High voltage power supply from HV battery |
|
| Cooling System | Temperature abnormally high |
|
| Shutdown Signal Circuit | Shutdown signal |
|
DTC PRIORITY LEVEL AND TROUBLE AREAS
Each DTC diagnostic procedure for the hybrid control system consists of a combination of the various relevant system (circuit) inspections.
When multiple DTCs are output, performing each diagnostic procedure in order of priority can lead to a more accurate diagnosis.
| DTC No. | Detection Item | Order of Priority | Inspection Pattern | ||||
|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 | |||
| Microcomputer Malfunction | Power Source Circuit Malfunction | Communication System Malfunction | Sensor and Actuator Circuit Malfunction | System Malfunction | |||
| P056014 | System Voltage (BATT) Circuit Short to Ground or Open | - | ○ | - | - | - | - |
| P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure | ○ | - | - | - | - | - |
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message | ○ | - | - | - | - | - |
| P060694 | Control Module Processor Unexpected Operation | ○ | - | - | - | - | - |
| P060A29 | Hybrid/EV Powertrain Control Module Monitoring Processor Signal Invalid | ○ | - | - | - | - | - |
| P060A44 | Hybrid/EV Powertrain Control Module Monitoring Processor Data Memory Failure | ○ | - | - | - | - | - |
| P060A45 | Hybrid/EV Powertrain Control Module Monitoring Processor Program Memory Failure | ○ | - | - | - | - | - |
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure | ○ | - | - | - | - | - |
| P060A49 | Hybrid/EV Powertrain Control Module Monitoring Processor Internal Electronic Failure | ○ | - | - | - | - | - |
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message | ○ | - | - | - | - | - |
| P060A94 | Internal Control Module Monitoring Processor Performance Unexpected Operation | ○ | - | - | - | - | - |
| P060B1C | Hybrid/EV Powertrain Control Module A/D Processing Voltage Out of Range | ○ | - | - | - | - | - |
| P060B49 | Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure | ○ | - | - | - | - | - |
| P060B71 | Hybrid/EV Powertrain Control Module A/D Processing Actuator Stuck | ○ | - | - | - | - | - |
| P062F44 | Hybrid/EV Powertrain Control Module EEPROM Data Memory Failure | ○ | - | - | - | - | - |
| P062F46 | Hybrid/EV Powertrain Control Module EEPROM Calibration / Parameter Memory Failure | ○ | - | - | - | - | - |
| P06881F | ECM/PCM Power Relay Sense Circuit Intermittent | - | ○ | - | - | - | - |
| P085011 | Park/Neutral Switch Circuit Short to Ground | - | - | - | ○ | - | - |
| P085015 | Park/Neutral Switch Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P08A662 | Gear Lever Position Sensor Signal Compare Failure | - | - | - | ○ | - | - |
| P0A0A13 | High Voltage System Interlock Circuit Open | - | - | - | - | ○ | - |
| P0A0A92 | High Voltage System Interlock Performance or Incorrect Operation | - | - | - | - | ○ | - |
| P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | ○ | - | - | - | - | - |
| P0A1B94 | Drive Motor "A" Control Module Unexpected Operation | ○ | - | - | - | - | - |
| P0A2A11 | Drive Motor "A" Temperature Sensor Circuit Short to Ground | - | - | - | ○ | - | - |
| P0A2A15 | Drive Motor "A" Temperature Sensor Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P0A2A1C | Drive Motor "A" Temperature Sensor Voltage Out of Range | - | - | - | ○ | - | - |
| P0A2A1F | Drive Motor "A" Temperature Sensor Circuit Intermittent | - | - | - | ○ | - | - |
| P0A3611 | Generator Temperature Sensor Circuit Short to Ground | - | - | - | ○ | - | - |
| P0A3615 | Generator Temperature Sensor Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P0A361C | Generator Temperature Sensor Voltage Out of Range | - | - | - | ○ | - | - |
| P0A361F | Generator Temperature Sensor Circuit Intermittent | - | - | - | ○ | - | - |
| P0A8111 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground | - | - | - | ○ | - | - |
| P0A8115 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P0A8196 | Hybrid/EV Battery Cooling Fan 1 Component Internal Failure | - | - | - | ○ | - | - |
| P0A9300 | Inverter "A" Cooling System Performance | - | - | - | - | ○ | B |
| P0A9563 | High Voltage Fuse Accumulated Load History | - | - | - | - | ○ | - |
| P0A9B11 | Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Ground | - | - | - | - | ○ | - |
| P0A9B15 | Hybrid/EV Battery Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P0A9B1C | Hybrid/EV Battery Temperature Sensor "A" Voltage Out of Range | - | - | - | ○ | - | - |
| P0A9B2A | Hybrid/EV Battery Temperature Sensor "A" Signal Stuck In Range | - | - | - | ○ | - | - |
| P0AA000 | Hybrid/EV Battery Positive Contactor Circuit Stuck Closed | - | - | - | - | ○ | - |
| P0AA073 | Hybrid/EV Battery Positive and Negative Contactor Actuator Stuck Closed | - | - | - | - | ○ | - |
| P0AA373 | Hybrid/EV Battery Negative Contactor Actuator Stuck Closed | - | - | - | - | ○ | - |
| P0AA649 | Hybrid/EV Battery Voltage System Insulation Resistance Decreased | - | - | - | - | ○ | - |
| P0AA749 | Hybrid/EV Battery Voltage Isolation Sensor Circuit Internal Electronic Failure | - | - | - | ○ | - | - |
| P0AAC11 | Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Ground | - | - | - | ○ | - | - |
| P0AAC15 | Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance | - | - | - | ○ | - | - |
| P0ABF11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground | - | - | - | ○ | - | - |
| P0ABF15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P0ABF28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure | - | - | - | ○ | - | - |
| P0ABF2A | Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range | - | - | - | ○ | - | - |
| P0AC511 | Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Ground | - | - | - | ○ | - | - |
| P0AC515 | Hybrid/EV Battery Temperature Sensor "B" Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P0AC51C | Hybrid/EV Battery Temperature Sensor "B" Voltage Out of Range | - | - | - | ○ | - | - |
| P0AC52A | Hybrid/EV Battery Temperature Sensor "B" Signal Stuck In Range | - | - | - | ○ | - | - |
| P0ACA11 | Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Ground | - | - | - | ○ | - | - |
| P0ACA15 | Hybrid/EV Battery Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P0ACA1C | Hybrid/EV Battery Temperature Sensor "C" Voltage Out of Range | - | - | - | ○ | - | - |
| P0ACA2A | Hybrid/EV Battery Temperature Sensor "C" Signal Stuck In Range | - | - | - | ○ | - | - |
| P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground | - | - | - | ○ | - | - |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | - | - | - | ○ | - | - |
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P0AE173 | Hybrid/EV Battery Precharge Contactor Actuator Stuck Closed | - | - | - | - | ○ | - |
| P0AE411 | Hybrid/EV Battery Precharge Contactor Circuit Short to Ground | - | - | - | ○ | - | - |
| P0AE415 | Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P0AFC00 | Hybrid/EV Battery Sensor Module | ○ | - | - | - | - | - |
| P0AFC16 | Hybrid/EV Battery Sensor Module Circuit Voltage Below Threshold | - | ○ | - | - | - | - |
| P0AFC49 | Hybrid/EV Battery Sensor Module Internal Electronic Failure | ○ | - | - | - | - | - |
| P0AFC62 | Hybrid/EV Battery Sensor Module Signal Compare Failure | ○ | - | - | - | - | - |
| P0AFC96 | Hybrid/EV Battery Sensor Module Component Internal Failure | ○ | - | - | - | - | - |
| P0B231C | Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range | - | - | - | ○ | - | - |
| P0B3B14 | Hybrid/EV Battery Voltage Sensor "A" Circuit Short to Ground or Open | - | - | - | ○ | - | - |
| P0B4014 | Hybrid/EV Battery Voltage Sensor "B" Circuit Short to Ground or Open | - | - | - | ○ | - | - |
| P0B4514 | Hybrid/EV Battery Voltage Sensor "C" Circuit Short to Ground or Open | - | - | - | ○ | - | - |
| P0B4A14 | Hybrid/EV Battery Voltage Sensor "D" Circuit Short to Ground or Open | - | - | - | ○ | - | - |
| P0B4F14 | Hybrid/EV Battery Voltage Sensor "E" Circuit Short to Ground or Open | - | - | - | ○ | - | - |
| P0B5414 | Hybrid/EV Battery Voltage Sensor "F" Circuit Short to Ground or Open | - | - | - | ○ | - | - |
| P0B5914 | Hybrid/EV Battery Voltage Sensor "G" Circuit Short to Ground or Open | - | - | - | ○ | - | - |
| P0B5E14 | Hybrid/EV Battery Voltage Sensor "H" Circuit Short to Ground or Open | - | - | - | ○ | - | - |
| P0B6314 | Hybrid/EV Battery Voltage Sensor "I" Circuit Short to Ground or Open | - | - | - | ○ | - | - |
| P0B6814 | Hybrid/EV Battery Voltage Sensor "J" Circuit Short to Ground or Open | - | - | - | ○ | - | - |
| P0C3000 | Hybrid/EV Battery State of Charge High | - | - | - | - | ○ | - |
| P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure | - | - | - | - | ○ | - |
| P0C7600 | Hybrid/EV Battery System Discharge Time Too Long | - | - | - | - | ○ | - |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range | - | - | - | - | ○ | - |
| P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range | - | - | - | - | ○ | - |
| P160600 | Collision detected or Collision Sensor Connection (Open) | - | - | - | - | - | - |
| P160604 | Collision detected or Collision Sensor Connection (Open) System Internal Failure | - | - | - | - | - | - |
| P183411 | Gear Lever Y Position Sensor 1 Circuit Short to Ground | - | - | - | ○ | - | - |
| P183415 | Gear Lever Y Position Sensor 1 Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P183A11 | Gear Lever Y Position Sensor 2 Circuit Short to Ground | - | - | - | ○ | - | - |
| P183A15 | Gear Lever Y Position Sensor 2 Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P183F12 | Gear Lever X Position Sensor 1 Circuit Short to Auxiliary Battery | - | - | - | ○ | - | - |
| P183F14 | Gear Lever X Position Sensor 1 Circuit Short to Ground or Open | - | - | - | ○ | - | - |
| P184512 | Gear Lever X Position Sensor 2 Circuit Short to Auxiliary Battery | - | - | - | ○ | - | - |
| P184514 | Gear Lever X Position Sensor 2 Circuit Short to Ground or Open | - | - | - | ○ | - | |
| P1A8000 | Hybrid/EV Battery Stack 1 Delta SOC High | - | - | - | - | ○ | - |
| P1AC000 | Hybrid/EV Battery Cell Low Voltage | - | - | - | - | ○ | - |
| P1AD01B | Hybrid/EV Battery Block Circuit Resistance Above Threshold | - | - | - | - | ○ | - |
| P1C2D62 | Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure | - | - | - | - | ○ | - |
| P1C6A9F | Motor Shutdown Stuck Off | - | - | - | - | ○ | - |
| P1C6C9F | Generator Shutdown Stuck Off | - | - | - | - | ○ | - |
| P1C7779 | Engine Failed to Start Mechanical Linkage Failure | - | - | - | ○ | - | - |
| P1C7C49 | Hybrid/EV Battery Voltage System (A/C Area) Insulation Resistance Decreased | - | - | - | - | ○ | - |
| P1C7D49 | Hybrid/EV Battery Voltage System (Hybrid/EV Battery Area) Insulation Resistance Decreased | - | - | - | - | ○ | - |
| P1C7E49 | Hybrid/EV Battery Voltage System (Transaxle Area) Insulation Resistance Decreased | - | - | - | - | ○ | - |
| P1C7F49 | Hybrid/EV Battery Voltage System (Direct Current Area) Insulation Resistance Decreased | - | - | - | - | ○ | - |
| P1C8149 | High Voltage Power Resource Circuit Consumption Circuit Short | - | - | - | - | ○ | - |
| P1C8249 | High Voltage Power Resource Circuit Over Loading | - | - | - | - | ○ | - |
| P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction | - | - | - | - | ○ | - |
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON | - | - | - | - | ○ | - |
| P1C8549 | High Voltage Power Resource Internal Electronic Failure | - | - | - | - | ○ | - |
| P1C8679 | Transmission (Input) Mechanical Linkage Failure | - | - | - | - | ○ | - |
| P1C8779 | Generator Mechanical Linkage Failure | - | - | - | - | ○ | - |
| P1C8879 | Planetary Gear Mechanical Linkage Failure | - | - | - | - | ○ | - |
| P1C9E9F | Hybrid/EV System Reset Stuck Off | - | - | - | - | ○ | - |
| P1C9F11 | Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Ground | - | - | - | ○ | - | - |
| P1C9F15 | Hybrid/EV Battery Current Sensor for Driving Control Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P1C9F1C | Hybrid/EV Battery Current Sensor for Driving Control Voltage Out of Range | - | - | - | ○ | - | - |
| P1CBB12 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery | - | - | - | ○ | - | - |
| P1CBB14 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open | - | - | - | ○ | - | |
| P1CBE1E | Hybrid/EV Battery Block 1 Voltage Difference Out of Range | - | - | - | - | ○ | - |
| P1CBF1E | Hybrid/EV Battery Block 2 Voltage Difference Out of Range | - | - | - | - | ○ | - |
| P1CC01E | Hybrid/EV Battery Block 3 Voltage Difference Out of Range | - | - | - | - | ○ | - |
| P1CC11E | Hybrid/EV Battery Block 4 Voltage Difference Out of Range | - | - | - | - | ○ | - |
| P1CC21E | Hybrid/EV Battery Block 5 Voltage Difference Out of Range | - | - | - | - | ○ | - |
| P1CC31E | Hybrid/EV Battery Block 6 Voltage Difference Out of Range | - | - | - | - | ○ | - |
| P1CC41E | Hybrid/EV Battery Block 7 Voltage Difference Out of Range | - | - | - | - | ○ | - |
| P1CC51E | Hybrid/EV Battery Block 8 Voltage Difference Out of Range | - | - | - | - | ○ | - |
| P1CC61E | Hybrid/EV Battery Block 9 Voltage Difference Out of Range | - | - | - | - | ○ | - |
| P1CE213 | PCU Interlock Circuit Open | - | - | - | - | ○ | - |
| P1CE292 | PCU Interlock Performance or Incorrect Operation | - | - | - | - | ○ | - |
| P1CE31C | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Voltage Out of Range | ○ | - | - | - | - | - |
| P1CE349 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Internal Electronic Failure | ○ | - | - | - | - | - |
| P1CE371 | Hybrid/EV Powertrain Control Module Monitoring Processor A/D Processing Actuator Stuck | ○ | - | - | - | - | - |
| P1CFA12 | IGB Signal Circuit Short to Auxiliary Battery | ○ | - | - | - | - | - |
| P212012 | Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Auxiliary Battery | - | - | - | ○ | - | - |
| P212014 | Throttle/Pedal Position Sensor/Switch "D" Circuit Short to Ground or Open | - | - | - | ○ | - | - |
| P21201C | Throttle/Pedal Position Sensor/Switch "D" Voltage Out of Range | - | - | - | ○ | - | - |
| P21201F | Throttle/Pedal Position Sensor/Switch "D" Circuit Intermittent | - | - | - | ○ | - | - |
| P212512 | Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Auxiliary Battery | - | - | - | ○ | - | - |
| P212514 | Throttle/Pedal Position Sensor/Switch "E" Circuit Short to Ground or Open | - | - | - | ○ | - | - |
| P21251C | Throttle/Pedal Position Sensor/Switch "E" Voltage Out of Range | - | - | - | ○ | - | - |
| P21251F | Throttle/Pedal Position Sensor/Switch "E" Circuit Intermittent | - | - | - | ○ | - | - |
| P213800 | Throttle/Pedal Position Sensor/Switch "D"/"E" Voltage Correlation | - | - | - | ○ | - | - |
| P21382B | Throttle/Pedal Position Sensor/Switch "D"/"E" Signal Cross Coupled | - | - | - | ○ | - | - |
| P253012 | IG2 Signal Circuit Short to Auxiliary Battery | ○ | - | - | - | - | - |
| P272C81 | Park Pawl Motor Invalid Serial Data Received | - | - | - | ○ | - | - |
| P274A11 | Transmission Fluid Temperature Sensor "C" Circuit Short to Ground | - | - | - | ○ | - | - |
| P274A15 | Transmission Fluid Temperature Sensor "C" Circuit Short to Auxiliary Battery or Open | - | - | - | ○ | - | - |
| P274A1C | Transmission Fluid Temperature Sensor "C" Voltage Out of Range | - | - | - | ○ | - | - |
| P274A1F | Transmission Fluid Temperature Sensor "C" Circuit Intermittent | - | - | - | ○ | - | - |
| P300000 | Hybrid/EV Battery Discharge Control Malfunction | - | - | - | - | ○ | - |
| P300016 | Hybrid/EV Battery Control System Circuit Voltage Below Threshold | - | - | - | - | ○ | - |
| P30004B | Hybrid/EV Battery Control System Over Temperature | - | - | - | - | ○ | - |
| P300449 | High Voltage Power Resource Circuit Short during Pre-Charge | - | - | - | - | ○ | - |
| P301100 | Hybrid/EV Battery Block 1 Circuit Resistance Out of Range (Extreme) | - | - | - | - | ○ | - |
| P30111E | Hybrid/EV Battery Block 1 Circuit Resistance Out of Range | - | - | - | - | ○ | - |
| P301200 | Hybrid/EV Battery Block 2 Circuit Resistance Out of Range (Extreme) | - | - | - | - | ○ | - |
| P30121E | Hybrid/EV Battery Block 2 Circuit Resistance Out of Range | - | - | - | - | ○ | - |
| P301300 | Hybrid/EV Battery Block 3 Circuit Resistance Out of Range (Extreme) | - | - | - | - | ○ | - |
| P30131E | Hybrid/EV Battery Block 3 Circuit Resistance Out of Range | - | - | - | - | ○ | - |
| P301400 | Hybrid/EV Battery Block 4 Circuit Resistance Out of Range (Extreme) | - | - | - | - | ○ | - |
| P30141E | Hybrid/EV Battery Block 4 Circuit Resistance Out of Range | - | - | - | - | ○ | - |
| P301500 | Hybrid/EV Battery Block 5 Circuit Resistance Out of Range (Extreme) | - | - | - | - | ○ | - |
| P30151E | Hybrid/EV Battery Block 5 Circuit Resistance Out of Range | - | - | - | - | ○ | - |
| P301600 | Hybrid/EV Battery Block 6 Circuit Resistance Out of Range (Extreme) | - | - | - | - | ○ | - |
| P30161E | Hybrid/EV Battery Block 6 Circuit Resistance Out of Range | - | - | - | - | ○ | - |
| P301700 | Hybrid/EV Battery Block 7 Circuit Resistance Out of Range (Extreme) | - | - | - | - | ○ | - |
| P30171E | Hybrid/EV Battery Block 7 Circuit Resistance Out of Range | - | - | - | - | ○ | - |
| P301800 | Hybrid/EV Battery Block 8 Circuit Resistance Out of Range (Extreme) | - | - | - | - | ○ | - |
| P30181E | Hybrid/EV Battery Block 8 Circuit Resistance Out of Range | - | - | - | - | ○ | - |
| P301900 | Hybrid/EV Battery Block 9 Circuit Resistance Out of Range (Extreme) | - | - | - | - | ○ | - |
| P30191E | Hybrid/EV Battery Block 9 Circuit Resistance Out of Range | - | - | - | - | ○ | - |
| P306562 | Hybrid/EV Battery Temperature Sensor "Group 1" Signal Compare Failure | - | - | - | ○ | - | - |
| P308A12 | Hybrid/EV Battery Voltage Sensor All Circuit Short to Auxiliary Battery | - | - | - | ○ | - | - |
| P308A13 | Hybrid/EV Battery Voltage Sensor All Circuit Open | - | - | - | ○ | - | - |
| P310711 | Lost Communication with Airbag System Control Module Circuit Short to Ground | - | - | ○ | - | - | - |
| P310715 | Lost Communication with Airbag System Control Module Circuit Short to Auxiliary Battery or Open | - | - | ○ | - | - | - |
| P310764 | Lost Communication with Airbag System Control Module Signal Plausibility Failure | - | - | ○ | - | - | - |
| P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message | - | - | ○ | - | - | - |
| P314779 | Transmission (Shaft) Mechanical Linkage Failure | - | - | - | - | ○ | - |
| P314A31 | Motor Electronics Coolant Pump "A" No Signal | - | - | - | ○ | - | - |
| P321E9F | Motor/Generator Shutdown Signal Stuck Off | - | - | - | - | ○ | - |
| P33B99F | Motor/Generator Shutdown Signal (Hybrid/EV Side) Stuck Off | - | - | - | - | ○ | - |
| P33BF9F | Motor/Generator Shutdown Signal (MG Side) Stuck Off | - | - | - | - | ○ | - |
| U010087 | Lost Communication with ECM/PCM "A" Missing Message | - | - | ○ | - | - | - |
| U010487 | Lost Communication with Cruise Control Module Missing Message | - | - | ○ | - | - | - |
| U011087 | Lost Communication with Drive Motor Control Module "A" Missing Message | - | - | ○ | - | - | - |
| U012287 | Lost Communication with Vehicle Dynamics Control Module Missing Message | - | - | ○ | - | - | - |
| U012987 | Lost Communication with Brake System Control Module Missing Message | - | - | ○ | - | - | - |
| U014000 | Lost Communication with Body Control Module (Sub) Missing Message | - | - | ○ | - | - | - |
| U014087 | Lost Communication with Body Control Module Missing Message | - | - | ○ | - | - | - |
| U015187 | Lost Communication with Restraints Control Module Missing Message | - | - | ○ | - | - | - |
| U016487 | Lost Communication with HVAC Control Module Missing Message | - | - | ○ | - | - | - |
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message | - | - | ○ | - | - | - |
| U029A87 | Lost Communication with Hybrid/EV Battery Sensor Module Missing Message | - | - | ○ | - | - | - |
| U042481 | HVAC Control Module to Hybrid Powertrain Control Module Invalid Serial Data Received | - | - | ○ | - | - | - |
| U110787 | Lost Communication with Power Management Module Missing Message | - | - | ○ | - | - | - |
| U117087 | Lost Communication with Brake System Control Module (Secondary CAN Line) Missing Message | - | - | ○ | - | - | - |
Tech Tips
The "Example of Multiple DTCs being Output" below is only one example of a malfunction condition. Therefore, a determination should not be made based on this alone.
Example of Multiple DTCs being Output:
The power supply of the microcomputer decreases while the vehicle is being driven.
DTCs are detected and the vehicle behavior is as follows.
P060B1C (Hybrid/EV Powertrain Control Module A/D Processing Voltage Out of Range): Microcomputer malfunction*
P06881F (ECM/PCM Power Relay Sense Circuit Intermittent): Power source circuit malfunction*
P0AA749 (Hybrid/EV Battery Voltage Isolation Sensor Circuit Internal Electronic Failure): Sensor and actuator circuit malfunction*
P0B231C (Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range): Sensor and actuator circuit malfunction*
P1C9E9F (Hybrid/EV System Reset Stuck Off): System malfunction*
*: Check the priority level in the "DTC Order of Priority" chart above.
System stopped
The inspection order of priority is: Microcomputer circuit → power source circuit → communication circuit → sensor and actuator circuit → system circuit. Therefore, check the repair procedure for P060B1C.
Follow the repair procedures and replace the hybrid vehicle control ECU. Finish the repair.
It is possible to check only the specified malfunctioning parts without having to check irrelevant parts.