2ZR-FXE BATTERY / CHARGING SERVICE DATA

Auxiliary battery voltage Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 20°C (68°F), Power switch off

12.0 V or higher

Auxiliary battery is OK

12.0 V or less

Recharge auxiliary battery

Fuse Standard resistance Below 1 Ω
Recharge auxiliary battery
Charge Method Charging Current
Normal Below 5 A
Quick Below 15 A
DC/DC CONVERTER
Item Tester Connection Condition Specified Condition
Current flowing from auxiliary battery Positive (+) auxiliary battery cable

Power switch on (READY)

(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.)

Below 0 A

(no current from auxiliary battery)

Auxiliary battery voltage Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 13 to 15 V