PROCEDURE
INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
Note
Do not apply voltage to any terminals except terminals 1 and 2 to avoid damaging the pulse sensor inside the motor.
Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly to the door.
| *a | Component without harness connected (Power Window Regulator Motor Assembly LH) |
| *b | Clockwise |
| *c | Counterclockwise |
| *d | Motor Gear |
Apply positive (+) auxiliary battery voltage to the connector terminal 2 (B).
Apply negative (-) auxiliary battery voltage to the connector terminals 1 (GND) and 7 (DOWN)/10 (UP).
Check that the motor gear rotates smoothly as follows.
| OK | ||||||
|---|---|---|---|---|---|---|
|
INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
Note
Do not apply voltage to any terminals except terminals 1 and 2 to avoid damaging the pulse sensor inside the motor.
Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly to the door.
| *a | Component without harness connected (Power Window Regulator Motor Assembly RH) |
| *b | Counterclockwise |
| *c | Clockwise |
| *d | Motor Gear |
Apply positive (+) auxiliary battery voltage to the connector terminal 2 (B).
Apply negative (-) auxiliary battery voltage to the connector terminals 1 (GND) and 7 (DOWN)/10 (UP).
Check that the motor gear rotates smoothly as follows.
| OK | ||||||
|---|---|---|---|---|---|---|
|