POWER WINDOW REGULATOR MOTOR(for Rear Side) INSPECTION

PROCEDURE


  1. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH

    Note


    • Do not apply voltage to any terminals except terminals 1 and 2 to avoid damaging the pulse sensor inside the motor.

    • Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly to the door.

      Click here


    1. A01CPG8C02
      *a

      Component without harness connected

      (Power Window Regulator Motor Assembly LH)

      *b Clockwise
      *c Counterclockwise
      *d Motor Gear

      Apply positive (+) auxiliary battery voltage to the connector terminal 2 (B).

    2. Apply negative (-) auxiliary battery voltage to the connector terminals 1 (GND) and 7 (DOWN)/10 (UP).

    3. Check that the motor gear rotates smoothly as follows.

      OK
      Measurement Condition Specified Condition

      Auxiliary battery positive (+) → 2 (B)

      Auxiliary battery negative (-): 1 (GND) (3 seconds or more) → 1 (GND) and 10 (UP) (within 1 second) → 1 (GND) (within 1 second) → 1 (GND) and 10 (UP)

      Motor gear rotates clockwise (UP)

      Auxiliary battery positive (+) → 2 (B)

      Auxiliary battery negative (-): 1 (GND) (3 seconds or more) → 1 (GND) and 7 (DOWN) (within 1 second) → 1 (GND) (within 1 second) → 1 (GND) and 7 (DOWN)

      Motor gear rotates counterclockwise (DOWN)
  2. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH

    Note


    • Do not apply voltage to any terminals except terminals 1 and 2 to avoid damaging the pulse sensor inside the motor.

    • Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly to the door.

      Click here


    1. A01CR1TC02
      *a

      Component without harness connected

      (Power Window Regulator Motor Assembly RH)

      *b Counterclockwise
      *c Clockwise
      *d Motor Gear

      Apply positive (+) auxiliary battery voltage to the connector terminal 2 (B).

    2. Apply negative (-) auxiliary battery voltage to the connector terminals 1 (GND) and 7 (DOWN)/10 (UP).

    3. Check that the motor gear rotates smoothly as follows.

      OK
      Measurement Condition Specified Condition

      Auxiliary battery positive (+) → 2 (B)

      Auxiliary battery negative (-): 1 (GND) (3 seconds or more) → 1 (GND) and 10 (UP) (within 1 second) → 1 (GND) (within 1 second) → 1 (GND) and 10 (UP)

      Motor gear rotates clockwise (UP)

      Auxiliary battery positive (+) → 2 (B)

      Auxiliary battery negative (-): 1 (GND) (3 seconds or more) → 1 (GND) and 7 (DOWN) (within 1 second) → 1 (GND) (within 1 second) → 1 (GND) and 7 (DOWN)