AIR CONDITIONING PRESSURE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL AIR CONDITIONER PRESSURE SENSOR


    1. Remove the vinyl tape from the liquid pipe sub-assembly and the connecting part of the air conditioner pressure sensor.

    2. Apply sufficient compressor oil to the O-ring of a new air conditioner pressure sensor and the connecting surface.

      Compressor Oil
      ND-OIL 11 or equivalent

      Note

      Keep the O-rings and O-ring fitting surfaces free of foreign matter.

    3. A01CNHOC01
      *a Turn
      *b Hold

      Using a 27 mm deep socket wrench, install the air conditioner pressure sensor.

      Torque:
      10.8 N*m  { 110 kgf*cm, 8 ft.*lbf }
    4. Connect the connector.

  2. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT


    1. for HFC-134a(R134a):

      Click here

    2. for HFO-1234yf(R1234yf):

      Click here

  3. WARM UP COMPRESSOR


    1. for HFC-134a(R134a):

      Click here

    2. for HFO-1234yf(R1234yf):

      Click here

  4. INSPECT FOR REFRIGERANT LEAK


    1. for HFC-134a(R134a):

      Click here

    2. for HFO-1234yf(R1234yf):

      Click here