PROCEDURE
INSTALL AIR CONDITIONER PRESSURE SENSOR
Remove the vinyl tape from the liquid pipe sub-assembly and the connecting part of the air conditioner pressure sensor.
Apply sufficient compressor oil to the O-ring of a new air conditioner pressure sensor and the connecting surface.
| Compressor Oil |
|---|
| ND-OIL 11 or equivalent |
Note
Keep the O-rings and O-ring fitting surfaces free of foreign matter.
| *a | Turn |
| *b | Hold |
Using a 27 mm deep socket wrench, install the air conditioner pressure sensor.
Connect the connector.
CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
for HFC-134a(R134a):
for HFO-1234yf(R1234yf):
WARM UP COMPRESSOR
for HFC-134a(R134a):
for HFO-1234yf(R1234yf):
INSPECT FOR REFRIGERANT LEAK
for HFC-134a(R134a):
for HFO-1234yf(R1234yf):