DESCRIPTION
The blower with fan motor sub-assembly is operated by signals from the air conditioning amplifier assembly. Blower motor speed signals are transmitted in accordance with changes in the duty ratio.
WIRING DIAGRAM
| *a | from Auxiliary Battery |
| *b | Blower with Fan Motor Sub-assembly |
| *c | Air Conditioning Amplifier Assembly |
CAUTION / NOTICE / HINT
Note
Inspect the fuses for circuits related to this system before performing the following procedure.
When the auxiliary battery is disconnected or the air conditioning amplifier assembly is replaced, be sure to perform servo motor initialization.
PROCEDURE
PERFORM ACTIVE TEST USING GTS
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower with fan motor sub-assembly | Min.: 0 Max.: 31 |
- |
| Tester Display |
|---|
| Blower Motor |
| OK |
|---|
| Blower with fan motor sub-assembly operates and changes speed. |
| Result | |||
|---|---|---|---|
|
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| NG |
|
CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR SUB-ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY, BATTERY AND BODY GROUND)
Disconnect the I50 air conditioning amplifier assembly connector.
Disconnect the I28 blower with fan motor sub-assembly connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK BLOWER WITH FAN MOTOR SUB-ASSEMBLY
| *a | Rear view of wire harness connector (to Air Conditioning Amplifier Assembly) |
Disconnect the air conditioning amplifier assembly connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE BLOWER WITH FAN MOTOR SUB-ASSEMBLY Click here |
| OK |
|
CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
| *a | Component with harness connected (Air Conditioning Amplifier Assembly) |
Remove the air conditioning amplifier assembly with its connectors still connected.
Turn the power switch on (IG).
Turn the blower switch LO.
Measure the waveform of the air conditioning amplifier assembly connector.
| OK |
|---|
| Waveform is similar to that shown in the illustration. |
Tech Tips
The waveform varies with the blower speed.
| Item | Content |
|---|---|
| Tester Connection | I50-22 (BLW) - I50-14 (GND) |
| Tool setting | 1 V/DIV., 500 μs/DIV. |
| Vehicle condition | Power switch on (IG) Blower switch LO |
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE BLOWER WITH FAN MOTOR SUB-ASSEMBLY Click here |
| NG |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |