COOLER EXPANSION VALVE REMOVAL

PROCEDURE


  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM


    1. for HFC-134a(R134a):

      Click here

    2. for HFO-1234yf(R1234yf):

      Click here

  2. DISCONNECT SUCTION PIPE SUB-ASSEMBLY

    Click here

  3. DISCONNECT LIQUID PIPE SUB-ASSEMBLY

    Click here

  4. REMOVE COOLER EXPANSION VALVE


    1. A01O8QR

      Using a 4 mm hexagon wrench, remove the 2 hexagon bolts.

    2. A01O82OC03
      *a 6 mm Bolt

      Temporarily install the 6 mm bolt halfway to the cooler expansion valve.

    3. A01O83Z

      Hold the bolt and pull it to remove the cooler expansion valve as shown in the illustration.

    4. A01O7NA

      Remove the 2 O-rings.