AIRBAG SYSTEM SRS Warning Light does not Come ON

DESCRIPTION

Refer to "SRS Warning Light Remains ON"

Click here

WIRING DIAGRAM

Refer to "SRS Warning Light Remains ON"

Click here

CAUTION / NOTICE / HINT

Note


  • After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

    Click here

  • When disconnecting the cable from the negative (-) auxiliary battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected.

    Click here

  • After replacing the airbag ECU assembly, refer to initialization.

    Click here

  • Inspect the fuses for circuits related to this system before performing the following inspection procedure.

  • When replaceing the combination meter assembly, make sure to replace it with a new one.

PROCEDURE


  1. CHECK AUXILIARY BATTERY


    1. Measure the auxiliary battery voltage with the power switch off.

      Standard voltage
      11 to 14 V
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK CONNECTION OF CONNECTORS


    1. Turn the power switch off.

    2. Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 90 seconds.

    3. Check that the connectors are properly connected to the combination meter assembly.

      Result
      Proceed to
      The connectors are properly connected
      The connectors are not properly connected

    The connectors are not properly connected
    The connectors are properly connected
  3. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)


    1. Turn the power switch off.

    2. B002KQPC15
      *a

      Front view of wire harness connector

      (to Combination Meter Assembly)

      Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 90 seconds.

    3. Disconnect the connector from the combination meter assembly.

    4. Connect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds.

    5. Turn the power switch on (IG).

    6. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      I10-21 (IG+) - Body ground Power switch on (IG) 11 to 14 V
      I10-22 (B) - Body ground Power switch off 11 to 14 V
    7. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      I10-40 (EP) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. CHECK SRS WARNING LIGHT (SHORT TO GROUND)


    1. Turn the power switch off.

    2. Disconnect the cable from the negative (-) auxiliary battery terminal, and wait for at least 90 seconds.

    3. Connect the connector to the combination meter assembly.

    4. Connect the cable to the negative (-) auxiliary battery terminal, and wait for at least 2 seconds.

    5. Turn the power switch on (IG).

    6. Check the SRS warning light condition.

      OK
      After the primary check period, the SRS warning light goes off for approximately 10 seconds and then remains on.

      Tech Tips

      The primary check period is approximately 6 seconds after the power switch is turned on (IG).

      Result
      Proceed to
      OK
      NG

    OK
    NG