THEFT DETERRENT SYSTEM Glass Breakage Sensor Circuit

DESCRIPTION

When the glass breakage sensor detects that the back door glass is tapped or broken, the sensor will set off the alarm for 30 seconds.

WIRING DIAGRAM

A01CNDPE01
*a Back Door Glass (Glass Breakage Sensor)
*b Main Body ECU (Multiplex Network Body ECU)

PROCEDURE


  1. READ VALUE USING GTS (GLASS BREAK SENSOR)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Main Body / Data List.

    5. According to the display on the GTS, read the Data List.


      Body Electrical > Main Body > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Sealed Glas Brak Sen Glass breakage sensor connecting With or Without

      With: Glass breakage sensor connected

      Without: Glass breakage sensor not connected

      -

      Body Electrical > Main Body > Data List
      Tester Display
      Sealed Glas Brak Sen
      OK
      "With" (glass breakage sensor operating) appears on GTS screen.
      Result
      Proceed to
      OK (for LHD)
      OK (for RHD)
      NG

    OK (for LHD)
    OK (for RHD)
    NG
  2. CHECK HARNESS AND CONNECTOR (MAIN BODY ECU [MULTIPLEX NETWORK BODY ECU] - GLASS BREAKAGE SENSOR AND BODY GROUND)


    1. Disconnect the I48 main body ECU (multiplex network body ECU) connector.

    2. Disconnect the Y2 back door glass (glass breakage sensor) connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      I48-7 (GPBS) - Y2-1 (SSR+) Always Below 1 Ω
      I48-7 (GPBS) - Body ground Always 10 kΩ or higher
      Y2-1 (SSR+) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. INSPECT BACK DOOR GLASS


    1. Disconnect the Y2 back door glass (glass breakage sensor) connector.

    2. A01CO5EE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (SSR+) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK (for LHD)
      OK (for RHD)
      NG

    OK (for LHD)
    OK (for RHD)
    NG