AUDIO AND VISUAL SYSTEM(for 8 Inch Display) Vehicle Speed Signal Circuit between Radio Receiver and Combination Meter

DESCRIPTION

The radio receiver assembly receives a vehicle speed signal from the combination meter assembly to control the ASL function.

Tech Tips


  • A voltage of 12 V or 5 V is output from each ECU and then input to the combination meter assembly. The signal is changed to a pulse signal at the transistor in the combination meter assembly. Each ECU controls its respective system based on this pulse signal.

  • If a short occurs in any of the ECUs or in the wire harness connected to an ECU, all systems in the diagram below will not operate normally.

WIRING DIAGRAM

B002HZPE33
*1 Combination Meter Assembly
*2 Radio Receiver Assembly

PROCEDURE


  1. CHECK COMBINATION METER ASSEMBLY (OUTPUT WAVEFORM)


    1. B002IYJC20
      *a

      Component with harness connected

      (Combination Meter Assembly)

      Check the output waveform.


      1. Remove the combination meter assembly with the connector still connected.

      2. Connect an oscilloscope to terminal I10-19 (+S) and body ground.

      3. Turn the power switch on (IG).

      4. Turn a wheel slowly.

      5. Check the signal waveform according to the condition(s) in the table below.

        Item Condition
        Measurement terminal I10-19 (+S) - Body ground
        Tool setting 5 V/DIV., 20 ms./DIV.
        Vehicle condition Wheel being rotated
        OK
        The waveform is similar to that shown in the illustration.

        Tech Tips

        When the system is functioning normally, one wheel revolution generates 4 pulses. As the vehicle speed increases, the width indicated by (A) in the illustration narrows.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (RADIO RECEIVER ASSEMBLY - COMBINATION METER ASSEMBLY)


    1. Disconnect the I152 radio receiver assembly connector.

    2. Disconnect the I10 combination meter assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      I152-27 (SPD) - I10-19 (+S) Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG