ULTRASONIC SENSOR(for Front) INSPECTION

PROCEDURE


  1. INSPECT NO. 1 ULTRASONIC SENSOR


    1. A01CQJRC01
      *a

      Component without harness connected

      (No. 1 Ultrasonic Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 20 to 40 kΩ

      If the result is not as specified, replace the No. 1 ultrasonic sensor.

  2. INSPECT NO. 2 ULTRASONIC SENSOR


    1. A01CQJRC01
      *a

      Component without harness connected

      (No. 2 Ultrasonic Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 20 to 40 kΩ

      If the result is not as specified, replace the No. 2 ultrasonic sensor.