ULTRASONIC SENSOR(for Front) INSPECTION

PROCEDURE


  1. INSPECT FRONT CENTER ULTRASONIC SENSOR


    1. B002KL3C02
      *a

      Component without harness connected

      (Front Center Ultrasonic Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (BI) - 6 (EI) Always 10 kΩ or higher
      4 (BI) - 1 (BO) Always Below 1 Ω
      5 (SI) - 2 (SO) Always Below 30 Ω
      6 (EI) - 3 (EO) Always Below 1 Ω

      If the result is not as specified, replace the front center ultrasonic sensor.

  2. INSPECT FRONT CORNER ULTRASONIC SENSOR


    1. B002KL3C03
      *a

      Component without harness connected

      (Front Corner Ultrasonic Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (BI) - 6 (EI) Always 10 kΩ or higher
      4 (BI) - 1 (BO) Always Below 1 Ω
      5 (SI) - 2 (SO) Always Below 30 Ω
      6 (EI) - 3 (EO) Always Below 1 Ω

      If the result is not as specified, replace the front corner ultrasonic sensor.