| DTC Code | DTC Name |
|---|---|
| P0E71-344 | Generator Torque Delivered Performance |
DTC SUMMARY
MALFUNCTION DESCRIPTION
This DTC indicates that the generator torque execution value does not correspond to the torque command value from the hybrid vehicle control ECU to the generator. The cause of this malfunction may be one of the following:
| Area | Main Malfunction Description | Step |
|---|---|---|
| Inverter low-voltage circuit | The connectors are not connected properly | 2 |
| Hybrid vehicle control ECU | Hybrid vehicle control ECU internal circuit malfunction | 3 |
| Generator (including generator cable) |
|
4 |
| Inside of inverter | Inverter with converter assembly internal circuit malfunction | 4 |
DESCRIPTION
For a description of the inverter.
When the actual generator torque is different from the generator torque requested by the MG ECU, the hybrid vehicle control ECU stores this DTC.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0E71-344 | Generator Torque Delivered Performance | Generator (MG1) torque execution monitoring malfunction: The difference between the generator torque requested by the hybrid vehicle control ECU and actual motor torque is large. (1 trip detection logic) |
|
Comes on | Master Warning Light: Comes on |
| DTC No. | Data List |
|---|---|
| P0E71-344 |
|
WIRING DIAGRAM
Refer to the wiring diagram for the generator high-voltage circuit.
Refer to the wiring diagram for the shut down signal circuit.
CAUTION / NOTICE / HINT
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Tech Tips
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (READY) and wait for 5 seconds or more.
Drive the vehicle for approximately 10 minutes mainly using the engine.
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check for DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Microcomputer malfunction | P0A1A-151, 166, 658, 791 | Generator Control Module |
| P0A1B-198, 786, 794 | Drive Motor "A" Control Module | |
| P0A1C-709, 710, 713, 797 | Drive Motor "B" Control Module | |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module | |
| P1C2A-155 | Generator A/D Converter Circuit | |
| P1C2B-192 | Drive Motor "A" A/D Converter Circuit | |
| P1C2C-706 | Drive Motor "B" A/D Converter Circuit | |
| P1CA6-156 | Generator Control Module Malfunction | |
| P1CA7-193 | Drive Motor Control Module Malfunction | |
| P1CA8-708 | Drive Motor "B" Control Module Malfunction | |
| P1CAC-200 | Generator Position Sensor Angle Malfunction | |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction | |
| P1CAE-715 | Drive Motor "B" Position Sensor Angle Malfunction | |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction | |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction | |
| P1CB1-798 | Drive Motor "B" Position Sensor REF Signal Cycle Malfunction | |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction | |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction | |
| P1CB4-799 | Drive Motor "B" Position Sensor REF Signal Stop Malfunction | |
| P3133-659 | Communication Error from Generator to Drive Motor "A" | |
| P3134-661 | Communication Error from Drive Motor "A" to Generator | |
| Power source circuit malfunction | P06B0-163 | Sensor Power Supply "A" Circuit / Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit / Open | |
| P06E6-164 | Sensor Power Supply "C" Circuit / Open | |
| P1C73-512 | Sensor Standard Voltage "F" Circuit / Open | |
| Sensor and actuator circuit malfunction | P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance | |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low | |
| P0A45-669 | Drive Motor "B" Position Sensor Circuit | |
| P0A46-671 | Drive Motor "B" Position Sensor Circuit Range / Performance | |
| P0A47-670 | Drive Motor "B" Position Sensor Circuit Low | |
| P0A4B-253 | Generator Position Sensor Circuit | |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance | |
| P0A4D-255 | Generator Position Sensor Circuit Low | |
| P0BEA-290 | Drive Motor "A" Phase V Current Sensor Circuit Range / Performance | |
| P0BEE-298 | Drive Motor "A" Phase W Current Sensor Circuit Range / Performance | |
| P0BF6-683 | Drive Motor "B" Phase V Current Sensor Circuit Range / Performance | |
| P0BFA-685 | Drive Motor "B" Phase W Current Sensor Circuit Range / Performance | |
| P0E05-328 | Generator Phase V Current Sensor Circuit Range / Performance | |
| P0E09-336 | Generator Phase W Current Sensor Circuit Range / Performance | |
| P1C3C-294 | Drive Motor "A" Phase V Current Sensor Correlation | |
| P1C3D-302 | Drive Motor "A" Phase W Current Sensor Correlation | |
| P1C3E-333 | Generator Phase V Current Sensor Correlation | |
| P1C3F-341 | Generator Phase W Current Sensor Correlation | |
| P1C4A-288 | Drive Motor "A" Phase V Current Sensor Sub Circuit Range / Performance | |
| P1C4F-296 | Drive Motor "A" Phase W Current Sensor Sub Circuit Range / Performance | |
| P1C54-326 | Generator Phase V Current Sensor Sub Circuit Range / Performance | |
| P1C59-334 | Generator Phase W Current Sensor Sub Circuit Range / Performance | |
| P1C6D-501 | Drive Motor "A" Phase V Current Sensor Offset Range / Performance | |
| P1C6E-502 | Drive Motor "A" Phase W Current Sensor Offset Range / Performance | |
| P1C6F-688 | Drive Motor "B" Phase V Current Sensor Offset Range / Performance | |
| P1C70-689 | Drive Motor "B" Phase W Current Sensor Offset Range / Performance | |
| P1C71-515 | Generator Phase V Current Sensor Offset Range / Performance | |
| P1C72-516 | Generator Phase W Current Sensor Offset Range / Performance | |
| P33C1-684 | Drive Motor "B" Phase V Current Sensor Sub Circuit Range / Performance | |
| P33C6-686 | Drive Motor "B" Phase W Current Sensor Sub Circuit Range / Performance | |
| P33D8-677 | Drive Motor "B" Phase V Current Sensor Correlation | |
| P33D9-678 | Drive Motor "A" Phase W Current Sensor Correlation | |
| System malfunction | P0A1A-517, 809 | Generator Control Module |
| P0A1B-503, 505, 547, 554, 806 | Drive Motor "A" Control Module | |
| P0A1C-693, 812 | Drive Motor "B" Control Module | |
| P0A40-504, 506, 549, 556, 808 | Drive Motor "A" Position Sensor Circuit Range / Performance | |
| P0A46-695, 814 | Drive Motor "B" Position Sensor Circuit Range / Performance | |
| P0A4C-518, 811 | Generator Position Sensor Circuit Range / Performance | |
| P0A78-279, 287, 548, 555, 807 | Drive Motor "A" Inverter Performance | |
| P0A79-694, 716, 813 | Drive Motor "B" Inverter Performance | |
| P0A7A-203, 325, 810 | Generator Inverter Performance | |
| P0AA6 (all INF codes)*1 | Hybrid Battery Voltage System Isolation Fault | |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long | |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range / Performance | |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low | |
| P0D30-267 | Drive Motor "A" Inverter Voltage Sensor Circuit High | |
| P0E32-585 | DC/DC Converter Voltage Sensor "A" Range / Performance | |
| P0E33-589 | DC/DC Converter Voltage Sensor "A" Low | |
| P0E34-590 | DC/DC Converter Voltage Sensor "A" High | |
| P1C2D-587 | Hybrid Battery Voltage / DC/DC Converter Voltage Correlation | |
| P3004-132 | High Voltage Power Resource | |
Tech Tips
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0E71-344 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check the connection condition of the low voltage connector of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Tech Tips
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK SHUT DOWN SIGNAL CIRCUIT
| Result | ||
|---|---|---|
|
| NEXT |
|
CHECK GENERATOR HIGH-VOLTAGE CIRCUIT
Tech Tips
If the "Generator High-voltage Circuit" inspection results are normal, perform the next step.
| Result | ||
|---|---|---|
|
| NEXT |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here |