| DTC Code | DTC Name |
|---|---|
| P0AE6-225 | Hybrid Battery Precharge Contactor Control Circuit Low |
DESCRIPTION
The SMRs (System Main Relays) are the relays that connect or disconnect the high voltage power system in accordance with commands from the hybrid vehicle control ECU.
There are 3 SMRs and 1 system main resistor. SMRB, SMRP, SMRG, and the system main resistor are located in the hybrid battery junction block assembly in the HV battery.
To connect to the high voltage power system, the vehicle will first turn on SMRP and SMRB to charge the vehicle through the system main resistor. Then, SMRP will be turned off after SMRG is turned on. To shut off the high voltage power system, SMRB and SMRG are turned off.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0AE6-225 | Hybrid Battery Precharge Contactor Control Circuit Low | Short to ground in the SMRP circuit: Primary circuit of SMRP is malfunctioning. (2 trip detection logic) |
|
Does not come on | Master Warning Light: Comes on |
| DTC No. | Data List |
|---|---|
| P0AE6-225 |
|
CAUTION / NOTICE / HINT
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Tech Tips
If DTC P0AE6-225 is output, the power switch cannot be turned on (READY).
After the repair, clear the DTCs, perform the following procedure and check that the same DTC (including pending DTC) is not output.
Turn the power switch off and wait for 30 seconds or more.
Turn the power switch on (READY) and wait for 30 seconds or more.
Turn the power switch off and wait for 60 seconds or more.
PROCEDURE
CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - BODY GROUND)
Disconnect the I115 hybrid vehicle control ECU connector.
| *a | Rear view of wire harness connector (to Hybrid Vehicle Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the I115 hybrid vehicle control ECU connector.
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE HYBRID VEHICLE CONTROL ECU Click here |
| NG |
|
CHECK CONNECTOR CONNECTION CONDITION (NO. 2 HYBRID BATTERY PACK WIRE CONNECTOR)
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check the connection condition of the No. 2 hybrid battery pack wire connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| A |
|
CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 2 hybrid vehicle battery shield reinforcement.
Disconnect the y1 hybrid battery junction block assembly connector.
Disconnect the I115 hybrid vehicle control ECU connector.
| *a | Rear view of wire harness connector (to Hybrid Vehicle Control ECU) |
| *b | Rear view of wire harness connector (to Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Reconnect the I115 hybrid vehicle control ECU connector.
Reconnect the y1 hybrid battery junction block assembly connector.
Install the No. 2 hybrid vehicle battery shield reinforcement.
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |