HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A92-261

DTC Code DTC Name
P0A92-261 Hybrid Generator Performance

DTC SUMMARY


  1. MALFUNCTION DESCRIPTION

    This DTC indicates that magnetic force deterioration of the permanent magnet located in the rotor inside the generator has been detected. The cause of this malfunction may be one of the following:

    Area Main Malfunction Description Step
    Inverter low-voltage circuit The connectors are not connected properly 3
    Hybrid vehicle control ECU Hybrid vehicle control ECU internal circuit malfunction 4
    Inside of inverter Inverter with converter assembly internal circuit malfunction 4
    Hybrid vehicle transaxle assembly (including generator cable)
    • Internal generator malfunction (entry of foreign matter, etc.)

    • Generator permanent magnet magnetic force deterioration

    • Open or short circuit in the generator coils

    • Defective generator cable connection condition

    • Open circuit or poor insulation in generator cable

    5

DESCRIPTION

For a description of the generator (MG1).

Click here

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0A92-261 Hybrid Generator Performance

Generator magnetic force deterioration or same phase short circuit:

Magnetic force of the generator decreases or a coil circuit in one of the 3 phases remains shorted for a certain period of time.

(1 trip detection logic)


  • Hybrid vehicle transaxle assembly

  • Inverter with converter assembly

  • Wire harness or connector

  • Hybrid vehicle control ECU

Comes on

Master Warning Light:

Comes on

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0AA6-526.

Click here

Refer to the wiring diagram for the shut down signal circuit.

Click here

CAUTION / NOTICE / HINT

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    Click here

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click here

Tech Tips

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.


  1. Drive the vehicle until the cumulative traveling time using the engine is a few minutes. (It is not necessary to drive continuously using the engine.)

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check for DTCs.


      Powertrain > Hybrid Control > Trouble Codes
      Result
      Result Proceed to
      P0A92-261 only is output, or DTCs except the ones in the table below are also output. A
      Any of the following DTCs are also output. B
      Malfunction Content Relevant DTC
      Microcomputer malfunction P0A1A-151, 166, 658, 791 Generator Control Module
      P0A1B-198, 786, 794 Drive Motor "A" Control Module
      P0A1C-709, 710, 713, 797 Drive Motor "B" Control Module
      P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
      P1C2A-155 Generator A/D Converter Circuit
      P1C2B-192 Drive Motor "A" A/D Converter Circuit
      P1C2C-706 Drive Motor "B" A/D Converter Circuit
      P1CA6-156 Generator Control Module Malfunction
      P1CA7-193 Drive Motor Control Module Malfunction
      P1CA8-708 Drive Motor "B" Control Module Malfunction
      P1CAC-200 Generator Position Sensor Angle Malfunction
      P1CAD-168 Drive Motor "A" Position Sensor Angle Malfunction
      P1CAE-715 Drive Motor "B" Position Sensor Angle Malfunction
      P1CAF-792 Generator Position Sensor REF Signal Cycle Malfunction
      P1CB0-795 Drive Motor "A" Position Sensor REF Signal Cycle Malfunction
      P1CB1-798 Drive Motor "B" Position Sensor REF Signal Cycle Malfunction
      P1CB2-793 Generator Position Sensor REF Signal Stop Malfunction
      P1CB3-796 Drive Motor "A" Position Sensor REF Signal Stop Malfunction
      P1CB4-799 Drive Motor "B" Position Sensor REF Signal Stop Malfunction
      P3133-659 Communication Error from Generator to Drive Motor "A"
      P3134-661 Communication Error from Drive Motor "A" to Generator
      Power source circuit malfunction P06B0-163 Sensor Power Supply "A" Circuit / Open
      P06D6-511 Sensor Reference Voltage "F" Circuit / Open
      P06E6-164 Sensor Power Supply "C" Circuit / Open
      P1C73-512 Sensor Standard Voltage "F" Circuit / Open
      Sensor and actuator circuit malfunction P0A3F-243 Drive Motor "A" Position Sensor Circuit
      P0A40-500 Drive Motor "A" Position Sensor Circuit Range / Performance
      P0A41-245 Drive Motor "A" Position Sensor Circuit Low
      P0A45-669 Drive Motor "B" Position Sensor Circuit
      P0A46-671 Drive Motor "B" Position Sensor Circuit Range / Performance
      P0A47-670 Drive Motor "B" Position Sensor Circuit Low
      P0A4B-253 Generator Position Sensor Circuit
      P0A4C-513 Generator Position Sensor Circuit Range / Performance
      P0A4D-255 Generator Position Sensor Circuit Low
      P0A51-174 Drive Motor "A" Current Sensor Circuit
      P0A55-687 Drive Motor "B" Current Sensor Circuit
      P0BEA-290 Drive Motor "A" Phase V Current Sensor Circuit Range / Performance
      P0BEE-298 Drive Motor "A" Phase W Current Sensor Circuit Range / Performance
      P0BF6-683 Drive Motor "B" Phase V Current Sensor Circuit Range / Performance
      P0BFA-685 Drive Motor "B" Phase W Current Sensor Circuit Range / Performance
      P0E05-328 Generator Phase V Current Sensor Circuit Range / Performance
      P0E09-336 Generator Phase W Current Sensor Circuit Range / Performance
      P1C3C-294 Drive Motor "A" Phase V Current Sensor Correlation
      P1C3D-302 Drive Motor "A" Phase W Current Sensor Correlation
      P1C3E-333 Generator Phase V Current Sensor Correlation
      P1C3F-341 Generator Phase W Current Sensor Correlation
      P1C4A-288 Drive Motor "A" Phase V Current Sensor Sub Circuit Range / Performance
      P1C4F-296 Drive Motor "A" Phase W Current Sensor Sub Circuit Range / Performance
      P1C54-326 Generator Phase V Current Sensor Sub Circuit Range / Performance
      P1C59-334 Generator Phase W Current Sensor Sub Circuit Range / Performance
      P1C6D-501 Drive Motor "A" Phase V Current Sensor Offset Range / Performance
      P1C6E-502 Drive Motor "A" Phase W Current Sensor Offset Range / Performance
      P1C6F-688 Drive Motor "B" Phase V Current Sensor Offset Range / Performance
      P1C70-689 Drive Motor "B" Phase W Current Sensor Offset Range / Performance
      P1C71-515 Generator Phase V Current Sensor Offset Range / Performance
      P1C72-516 Generator Phase W Current Sensor Offset Range / Performance
      P33C1-684 Drive Motor "B" Phase V Current Sensor Sub Circuit Range / Performance
      P33C6-686 Drive Motor "B" Phase W Current Sensor Sub Circuit Range / Performance
      P33D8-677 Drive Motor "B" Phase V Current Sensor Correlation
      P33D9-678 Drive Motor "A" Phase W Current Sensor Correlation
      System malfunction P0A7A-203 Generator Inverter Performance
      P0A90-509 Drive Motor "A" Performance
      P0A91-702 Drive Motor "B" Performance
      P0A92-521 Hybrid Generator Performance
      P0AA6 (all INF codes)*1 Hybrid Battery Voltage System Isolation Fault
      P0C19-306 Drive Motor "A" Torque Delivered Performance
      P0C1A-704 Drive Motor "B" Torque Delivered Performance
      P0C76-523 Hybrid Battery System Discharge Time Too Long
      P0D2E-586 Drive Motor "A" Inverter Voltage Sensor Circuit Range / Performance
      P0D2F-266 Drive Motor "A" Inverter Voltage Sensor Circuit Low
      P0D30-267 Drive Motor "A" Inverter Voltage Sensor Circuit High
      P0E32-585 DC/DC Converter Voltage Sensor "A" Range / Performance
      P0E33-589 DC/DC Converter Voltage Sensor "A" Low
      P0E34-590 DC/DC Converter Voltage Sensor "A" High
      P0E71-344 Generator Torque Delivered Performance
      P1C2D-587 Hybrid Battery Voltage / DC/DC Converter Voltage Correlation
      P3004-132 High Voltage Power Resource

      Tech Tips


      • *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

      • P0A92-261 may be output as a result of the malfunction indicated by the DTCs above.


        1. The chart above is listed in inspection order of priority.

        2. Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)

    5. Turn the power switch off.


    B
    A
  2. SIMULATION TEST


    1. Turn the power switch on (READY).

    2. Connect the GTS to the DLC3.

    3. Clear the DTCs.

    4. Drive the vehicle until the cumulative traveling time using the engine is a few minutes. (It is not necessary to drive continuously using the engine.)

      Tech Tips

      If the accelerator pedal is depressed with the shift lever in P, the engine will start.

    5. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    6. Check for DTCs.


      Powertrain > Hybrid Control > Trouble Codes
      Result
      Proceed to
      P0A92-261 is output or no DTCs are output.
      Except P0A92-261 is output.
    7. Turn the power switch off.


    Except P0A92-261 is output.
    P0A92-261 is output or no DTCs are output.
  3. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

    Result
    Result Proceed to
    OK A
    NG (The connector is not connected securely.) B
    NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. B002I4J

      Check the connection condition of the low voltage connector of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.

      Click here

      Note

      Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

      OK
      - The connector is connected securely.
      - The terminals are not deformed and are connected securely.
      - No water or foreign matter in the connector.
      Result
      Result Proceed to
      OK A
      NG (The connector is not connected securely.) B
      NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C

      Tech Tips

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.


    B
    C
    A
  4. CHECK SHUT DOWN SIGNAL CIRCUIT

    Click here

    Result
    Proceed to
    NEXT

    NEXT
  5. CHECK GENERATOR HIGH-VOLTAGE CIRCUIT

    Click here

    Tech Tips

    If the "Generator High-voltage Circuit" inspection results are normal, perform the next step.

    Result
    Proceed to
    NEXT

    NEXT