| DTC Code | DTC Name |
|---|---|
| P0A1A-151 | Generator Control Module |
| P0A1A-155 | Generator Control Module |
| P0A1A-156 | Generator Control Module |
| P0A1A-166 | Generator Control Module |
| P0A1A-658 | Generator Control Module |
| P0A1A-659 | Generator Control Module |
| P0A1A-791 | Generator Control Module |
| P0A1B-163 | Drive Motor "A" Control Module |
| P0A1B-164 | Drive Motor "A" Control Module |
| P0A1B-192 | Drive Motor "A" Control Module |
| P0A1B-193 | Drive Motor "A" Control Module |
| P0A1B-198 | Drive Motor "A" Control Module |
| P0A1B-511 | Drive Motor "A" Control Module |
| P0A1B-512 | Drive Motor "A" Control Module |
| P0A1B-661 | Drive Motor "A" Control Module |
| P0A1B-786 | Drive Motor "A" Control Module |
| P0A1B-794 | Drive Motor "A" Control Module |
| P0A1C-706 | Drive Motor "B" Control Module |
| P0A1C-708 | Drive Motor "B" Control Module |
| P0A1C-709 | Drive Motor "B" Control Module |
| P0A1C-710 | Drive Motor "B" Control Module |
| P0A1C-713 | Drive Motor "B" Control Module |
| P0A1C-797 | Drive Motor "B" Control Module |
DESCRIPTION
The MG ECU, which is built into the inverter with converter assembly, monitors its internal operation and will store DTCs if the system is malfunctioning. If any of the following DTCs are output, replace the inverter with converter assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A1A-151 | Generator Control Module | MG ECU internal malfunction: Run pulse signal cycle deviation or stop (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-155 | Generator Control Module | MG ECU internal malfunction: A/D converter malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-156 | Generator Control Module | MG ECU internal malfunction: CPU ROM-RAM error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-166 | Generator Control Module | MG ECU internal malfunction: R/D converter NM stop error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-658 | Generator Control Module | MG ECU internal malfunction: Calculation check error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-659 | Generator Control Module | MG ECU internal malfunction: Communication error (from generator (MG1) to motor (MG2)) (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1A-791 | Generator Control Module | MG ECU internal malfunction: R/D converter communication error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-163 | Drive Motor "A" Control Module | MG ECU internal malfunction: IPM positive power source error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-164 | Drive Motor "A" Control Module | MG ECU internal malfunction: IPM negative power source error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-192 | Drive Motor "A" Control Module | MG ECU internal malfunction: A/D converter malfunction (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-193 | Drive Motor "A" Control Module | MG ECU internal malfunction: CPU ROM-RAM error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-198 | Drive Motor "A" Control Module | MG ECU internal malfunction: R/D converter NM stop error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-511 | Drive Motor "A" Control Module | MG ECU internal malfunction: Standard voltage for analog signal offset (+2.5 V) error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-512 | Drive Motor "A" Control Module | MG ECU internal malfunction: Standard voltage for analog signal (+5 V) error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-661 | Drive Motor "A" Control Module | MG ECU internal malfunction: Communication error (from motor (MG2) to generator (MG1)) (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-786 | Drive Motor "A" Control Module | MG ECU internal malfunction: Calculation check error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1B-794 | Drive Motor "A" Control Module | MG ECU internal malfunction: R/D converter communication error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1C-706 | Drive Motor "B" Control Module | MG ECU internal malfunction: CPU ROM-RAM error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1C-708 | Drive Motor "B" Control Module | MG ECU internal malfunction: CPU ROM-RAM error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1C-709 | Drive Motor "B" Control Module | MG ECU internal malfunction: R/D converter communication error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1C-710 | Drive Motor "B" Control Module | MG ECU internal malfunction: Calculation check error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1C-713 | Drive Motor "B" Control Module | MG ECU internal malfunction: R/D converter NM stop error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| P0A1C-797 | Drive Motor "B" Control Module | MG ECU internal malfunction: R/D converter communication error (1 trip detection logic) |
Inverter with converter assembly | Comes on | Master Warning Light: Comes on |
| DTC No. | Data List |
|---|---|
| P0A1A-791 | Generator (MG1) Rev |
| P0A1B-794 | Motor (MG2) Revolution |
| P0A1C-797 | Rear Motor Revolution |
| P0A1A-151 P0A1A-155 P0A1A-156 P0A1A-166 P0A1A-658 P0A1A-659 P0A1B-163 P0A1B-164 P0A1B-192 P0A1B-193 P0A1B-511 P0A1B-512 P0A1B-661 P0A1B-786 P0A1C-706 P0A1C-708 P0A1C-709 P0A1C-710 P0A1C-713 |
- |
CAUTION / NOTICE / HINT
Tech Tips
If DTC P0A1A-151, P0A1A-155, P0A1A-658, P0A1A-659, P0A1A-791, P0A1B-163, P0A1B-164, P0A1B-192, P0A1B-511, P0A1B-512, P0A1B-661, P0A1B-786, P0A1B-794, P0A1C-706, P0A1C-709, P0A1C-710 or P0A1C-797 is output, clear the DTCs, perform the following procedure, and check that the same DTC is not output after the repair.
Turn the power switch on (IG) and wait for 5 seconds or more.
If DTC P0A1A-156, P0A1B-193 or P0A1C-708 is output, clear the DTCs, perform the following procedure, and check that the same DTC is not output after the repair.
Turn the power switch on (IG) and wait for 1 minute or more.
If DTC P0A1A-166 is output, clear the DTCs, perform the following procedure, and check that the same DTC is not output after the repair.
Turn the power switch on (READY).
With the vehicle stopped and the shift lever in P, depress the accelerator pedal and start the engine.
Depress the accelerator pedal and keep the engine running for 30 seconds or more.
If DTC P0A1B-198 or P0A1C-713 is output, clear the DTCs, perform the following procedure, and check that the same DTC is not output after the repair.
Turn the power switch on (READY).
Drive the vehicle at 5 km/h (3 mph) or more for 30 seconds or more.