CAMSHAFT OIL CONTROL VALVE INSPECTION

PROCEDURE


  1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 6.9 to 7.9 Ω

      If the result is not as specified, replace the camshaft timing oil control valve assembly.

    2. A01COPRC01
      *a

      Component without harness connected

      (Camshaft Timing Oil Control Valve Assembly)

      Connect the battery positive (+) lead to terminal 1 and negative (-) lead to terminal 2 and check the movement of the valve.

      OK
      Condition Specified Condition
      Battery positive (+) voltage is applied Valve moves in left arrow direction shown in illustration
      Battery positive (+) voltage is cut off Valve moves in right arrow direction shown in illustration

      If the result is not as specified, replace the camshaft timing oil control valve assembly. If the valve cannot return properly because of foreign matter, a small pressure leak in the advanced direction may occur and a DTC may be stored.