2AR-FXE BATTERY / CHARGING SERVICE DATA

Auxiliary battery voltage Positive (+) terminal - Negative (-) terminal 20°C (68°F), Power switch off

12.5 V or higher

Auxiliary battery is OK

11.0 to 12.5 V

Recharge auxiliary battery

Below 11.0 V

Replace auxiliary battery

Recharge auxiliary battery LN2 5 A or less
Fuse Standard resistance Below 1 Ω
DC/DC converter assembly Current flowing from auxiliary battery Auxiliary battery positive cable

Power switch on (READY)

(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.)

0 A or less

(no current from auxiliary battery)

Auxiliary battery voltage Positive (+) terminal - Negative (-) terminal 13.8 to 14.7 V
Auxiliary battery thermometer sensor Standard Resistance 1 - 2 3.00 to 3.73 kΩ at 10°C (50°F)
2.45 to 2.88 kΩ at 15°C (59°F)
1.95 to 2.30 kΩ at 20°C (68°F)
1.60 to 1.80 kΩ at 25°C (77°F)
1.28 to 1.47 kΩ at 30°C (86°F)
1.00 to 1.22 kΩ at 35°C (95°F)
0.80 to 1.00 kΩ at 40°C (104°F)
0.65 to 0.85 kΩ at 45°C (113°F)
0.50 to 0.70 kΩ at 50°C (122°F)
0.44 to 0.60 kΩ at 55°C (131°F)
0.36 to 0.50 kΩ at 60°C (140°F)