BACK DOOR OPENER SWITCH INSPECTION

PROCEDURE


  1. INSPECT BACK DOOR OPENER SWITCH ASSEMBLY (w/ Smart Entry and Start System)


    1. Check the operation of the opener switch.


      1. A018JBOC51
        *a

        Component without harness connected

        (Back Door Opener Switch Assembly)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        2 (GND) - 3 (BDSU) Back door opener switch not pushed 10 kΩ or higher
        2 (GND) - 3 (BDSU) Back door opener switch pushed Below 1 Ω

        If the result is not as specified, replace the back door opener switch assembly.

    2. Check the operation of the lock switch.


      1. A018JBOC52
        *a

        Component without harness connected

        (Back Door Opener Switch Assembly)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (TSW5) - 2 (GND) Back door lock switch not pushed 10 kΩ or higher
        1 (TSW5) - 2 (GND) Back door lock switch pushed Below 1 Ω

        If the result is not as specified, replace the back door opener switch assembly.

  2. INSPECT BACK DOOR OPENER SWITCH ASSEMBLY (w/o Smart Entry and Start System)


    1. Check the operation of the opener switch.


      1. A018JBOC51
        *a

        Component without harness connected

        (Back Door Opener Switch Assembly)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        2 (GND) - 3 (BDSU) Back door opener switch not pushed 10 kΩ or higher
        2 (GND) - 3 (BDSU) Back door opener switch pushed Below 1 Ω

        If the result is not as specified, replace the back door opener switch assembly.