POWER WINDOW REGULATOR MOTOR(for Front Door) INSPECTION

PROCEDURE


  1. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH


    1. A018LOJC03
      *a

      Component without harness connected

      (Power Window Regulator Motor Assembly LH)

      *b Counterclockwise
      *c Clockwise

      Connect a positive (+) battery lead to terminal 2 (B).

      Note

      Do not connect a positive (+) battery lead to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.

    2. Connect a negative (-) battery lead to terminals 1 (GND) and 7 (DOWN) or 10 (UP).

    3. Check that the motor gear rotates smoothly as follows:

      OK
      Battery Connection Specified Condition

      1. Connect a positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 10 (UP).

      3. Disconnect and reconnect the negative (-) battery lead to terminal 10 (UP) within 1 second.

      Motor gear rotates clockwise

      1. Connect a positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 7 (DOWN).

      3. Disconnect and reconnect the negative (-) battery lead to terminal 7 (DOWN) within 1 second.

      Motor gear rotates counterclockwise

      • If the result is not as specified, replace the power window regulator motor assembly LH.

      Note

      Initialize the power window control system after installing the power window regulator motor and regulator assembly.

  2. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH


    1. A018JBHC02
      *a

      Component without harness connected

      (Power Window Regulator Motor Assembly RH)

      *b Clockwise
      *c Counterclockwise

      Connect a positive (+) battery lead to terminal 2 (B).

      Note

      Do not connect a positive (+) battery lead to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.

    2. Connect a negative (-) battery lead to terminals 1 (GND) and 7 (DOWN) or 10 (UP).

    3. Check that the motor gear rotates smoothly as follows:

      OK
      Battery Connection Specified Condition

      1. Connect a positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 10 (UP).

      3. Disconnect and reconnect the negative (-) battery lead to terminal 10 (UP) within 1 second.

      Motor gear rotates counterclockwise

      1. Connect a positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 7 (DOWN).

      3. Disconnect and reconnect the negative (-) battery lead to terminal 7 (DOWN) within 1 second.

      Motor gear rotates clockwise

      • If the result is not as specified, replace the power window regulator motor assembly RH.

      Note

      Initialize the power window control system after installing the power window regulator motor and regulator assembly.