RELAY ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT G/H NO. 1 RELAY


    1. A018LUQ

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 4 Battery voltage applied to terminals 1 and 2 10 kΩ or higher
      3 - 4 Battery voltage not applied between terminals Below 1 Ω
      3 - 5 Battery voltage applied to terminals 1 and 2 Below 1 Ω
      3 - 5 Battery voltage not applied between terminals 10 kΩ or higher
      4 - 5 Always 10 kΩ or higher

      If the result is not as specified, replace the G/H No. 1 relay.