DATA LIST
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Tech Tips
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature | Min.: -30.80°C (-23.44°F) Max.: 50.80°C (123.44°F) |
- | - |
| Evaporator Fin Thermistor | No. 1 cooler thermistor | Min.: -30.00°C (-22.00°F) Max.: 59.60°C (139.28°F) |
Actual evaporator temperature displayed | - |
| Evaporator Target Temp | Evaporator target temperature | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | - |
| Engine Coolant Temp | Engine coolant temperature sensor | Min.: 1.30°C (34.34°F) Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed | - |
| Blower Motor Speed Level | Blower motor speed level | Min.: 0 Max.: 31 |
Displayed speed level increases between 0 and 31 as blower motor speed increases | - |
| Regulator Pressure Sensor | Air conditioner tube and accessory assembly | Min.: -456.6 kPaG Max.: 3294.3 kPaG |
Actual refrigerant pressure displayed | - |
| Regulator Control Current | Solenoid valve control current | Min.: 0 A Max.: 0.997 A |
Displayed value changes between 0 A and 0.997 A in accordance with solenoid valve operation | - |
| Evap Temp Sensor (Rear) | Rear evaporator temperature sensor | Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual rear evaporator temperature displayed | - |
| Blower Motor Level (Rear) | Rear blower motor speed level | Min.: 0 Max.: 31 |
Displayed speed level increases between 0 and 31 as rear blower motor speed increases | - |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air mix) target pulse | Min.: 128 Max.: 383 |
|
- |
| Air Mix Servo Actual Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air mix) actual pulse | Min.: 128 Max.: 383 |
|
- |
| Air Outlet Servo Pulse (D) | No. 1 air conditioning radiator damper servo sub-assembly (air outlet) target pulse | Min.: 128 Max.: 383 |
|
- |
| Air Outlet Servo Actu Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse | Min.: 128 Max.: 383 |
|
- |
| Air Inlet Damper Targ Pulse | Blower damper servo sub-assembly (air inlet) target pulse | Min.: 128 Max.: 383 |
|
- |
| Air Inlet Damper Actual Pulse | Blower damper servo sub-assembly (air inlet) actual pulse | Min.: 128 Max.: 383 |
|
- |
| Evaporator Control | Evaporator control | Auto or Manual | Customized value displayed | - |
| Refrigerant Shortage Check | Refrigerant shortage check | ON or OFF | Customized value displayed | - |
| Air Mix Servo Targ Pls(F&R D) | Rear air mix damper servo sub-assembly target pulse | Min.: 128 Max.: 383 |
|
- |
| A/M Servo Actual Pulse(F&R D) | Rear air mix damper servo sub-assembly actual pulse | Min.: 128 Max.: 383 |
|
- |
| Air Outlet Servo Pls (F&R D) | Rear mode damper servo sub-assembly target pulse | Min.: 128 Max.: 383 |
|
- |
| A/O Servo Actual Pulse(F&R D) | Rear mode damper servo sub-assembly actual pulse | Min.: 128 Max.: 383 |
|
- |
| A/C Cutoff Signal | Air conditioning control cutoff signal | OFF or ON | The ECM sends the air conditioning control cutoff signal displayed | - |
| Refrigerant Gas Type | Refrigerant gas type | R134a or 1234yf | Refrigerant gas type displayed | - |
| Number of Trouble Codes | Number of trouble codes | Min.: 0 Max.: 255 |
Number of DTCs displayed | - |
ACTIVE TEST
Tech Tips
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0 Max.: 31 |
- |
| Magnetic Clutch Relay | Air conditioning system operation | OFF or ON | - |
| Defogger Relay (Rear) | Rear window defogger | OFF or ON | - |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse | Min.: 128 Max.: 383 |
Operates between 7 to 105 pulses |
| Air Outlet Servo Pulse (D) | No. 1 air conditioning radiator damper servo sub-assembly (air outlet) pulse | Min.: 128 Max.: 383 |
Operates between 8 to 97 pulses |
| Air Inlet Damper Targ Pulse | Blower damper servo sub-assembly (air inlet) pulse | Min.: 128 Max.: 383 |
Operates between 7 to 28 pulses |
| Rear Blower Motor | Rear blower motor with fan sub-assembly | Min.: 0 Max.: 31 |
- |
| A/M Servo Pulse(F&R D) | Rear air mix damper servo sub-assembly pulse | Min.: 128 Max.: 383 |
Operates between 9 to 54 pulses |
| A/O Servo Pulse(F&R D) | Rear mode damper servo sub-assembly pulse | Min.: 128 Max.: 383 |
Operates between 7 to 83 pulses |