AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) DATA LIST / ACTIVE TEST


  1. DATA LIST

    Note

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

    Tech Tips

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Check the value(s) by referring to the table below.


      Body Electrical > Air Conditioner > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Ambient Temp Sensor Thermistor assembly

      Min.: -23.30°C (-9.94°F)

      Max.: 65.95°C (150.71°F)

      Actual ambient temperature displayed -
      Adjusted Ambient Temp Adjusted ambient temperature

      Min.: -30.80°C (-23.44°F)

      Max.: 50.80°C (123.44°F)

      - -
      Evaporator Fin Thermistor No. 1 cooler thermistor

      Min.: -30.00°C (-22.00°F)

      Max.: 59.60°C (139.28°F)

      Actual evaporator temperature displayed -
      Evaporator Target Temp Evaporator target temperature

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Evaporator target temperature displayed -
      Engine Coolant Temp Engine coolant temperature sensor

      Min.: 1.30°C (34.34°F)

      Max.: 90.55°C (194.99°F)

      Actual engine coolant temperature displayed -
      Blower Motor Speed Level Blower motor speed level

      Min.: 0

      Max.: 31

      Displayed speed level increases between 0 and 31 as blower motor speed increases -
      Regulator Pressure Sensor Air conditioner tube and accessory assembly

      Min.: -456.6 kPaG

      Max.: 3294.3 kPaG

      Actual refrigerant pressure displayed -
      Regulator Control Current Solenoid valve control current

      Min.: 0 A

      Max.: 0.997 A

      Displayed value changes between 0 A and 0.997 A in accordance with solenoid valve operation -
      Evap Temp Sensor (Rear) Rear evaporator temperature sensor

      Min.: -29.70°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual rear evaporator temperature displayed -
      Blower Motor Level (Rear) Rear blower motor speed level

      Min.: 0

      Max.: 31

      Displayed speed level increases between 0 and 31 as rear blower motor speed increases -
      Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) target pulse

      Min.: 128

      Max.: 383


      • MAX COLD: 105 (pulse)

      • MAX HOT: 7 (pulse)

      -
      Air Mix Servo Actual Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) actual pulse

      Min.: 128

      Max.: 383


      • MAX COLD: 105 (pulse)

      • MAX HOT: 7 (pulse)

      -
      Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) target pulse

      Min.: 128

      Max.: 383


      • FACE: 8 (pulse)

      • B/L: 30 (pulse)

      • FOOT: 74 (pulse)

      • FOOT/DEF: 80 (pulse)

      • DEF: 97 (pulse)

      -
      Air Outlet Servo Actu Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse

      Min.: 128

      Max.: 383


      • FACE: 8 (pulse)

      • B/L: 30 (pulse)

      • FOOT: 74 (pulse)

      • FOOT/DEF: 80 (pulse)

      • DEF: 97 (pulse)

      -
      Air Inlet Damper Targ Pulse Blower damper servo sub-assembly (air inlet) target pulse

      Min.: 128

      Max.: 383


      • Recirculation: 7 (pulse)

      • Fresh: 28 (pulse)

      -
      Air Inlet Damper Actual Pulse Blower damper servo sub-assembly (air inlet) actual pulse

      Min.: 128

      Max.: 383


      • Recirculation: 7 (pulse)

      • Fresh: 28 (pulse)

      -
      Evaporator Control Evaporator control Auto or Manual Customized value displayed -
      Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
      Air Mix Servo Targ Pls(F&R D) Rear air mix damper servo sub-assembly target pulse

      Min.: 128

      Max.: 383


      • MAX COLD: 9 (pulse)

      • MAX HOT: 54 (pulse)

      -
      A/M Servo Actual Pulse(F&R D) Rear air mix damper servo sub-assembly actual pulse

      Min.: 128

      Max.: 383


      • MAX COLD: 9 (pulse)

      • MAX HOT: 54 (pulse)

      -
      Air Outlet Servo Pls (F&R D) Rear mode damper servo sub-assembly target pulse

      Min.: 128

      Max.: 383


      • FACE: 83 (pulse)

      • B/L: 38 (pulse)

      • FOOT: 7 (pulse)

      -
      A/O Servo Actual Pulse(F&R D) Rear mode damper servo sub-assembly actual pulse

      Min.: 128

      Max.: 383


      • FACE: 83 (pulse)

      • B/L: 38 (pulse)

      • FOOT: 7 (pulse)

      -
      A/C Cutoff Signal Air conditioning control cutoff signal OFF or ON The ECM sends the air conditioning control cutoff signal displayed -
      Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed -
      Number of Trouble Codes Number of trouble codes

      Min.: 0

      Max.: 255

      Number of DTCs displayed -
  2. ACTIVE TEST

    Tech Tips

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Check the operation by referring to the table below.


      Body Electrical > Air Conditioner > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      Blower Motor Blower motor with fan sub-assembly

      Min.: 0

      Max.: 31

      -
      Magnetic Clutch Relay Air conditioning system operation OFF or ON -
      Defogger Relay (Rear) Rear window defogger OFF or ON -
      Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse

      Min.: 128

      Max.: 383

      Operates between 7 to 105 pulses
      Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) pulse

      Min.: 128

      Max.: 383

      Operates between 8 to 97 pulses
      Air Inlet Damper Targ Pulse Blower damper servo sub-assembly (air inlet) pulse

      Min.: 128

      Max.: 383

      Operates between 7 to 28 pulses
      Rear Blower Motor Rear blower motor with fan sub-assembly

      Min.: 0

      Max.: 31

      -
      A/M Servo Pulse(F&R D) Rear air mix damper servo sub-assembly pulse

      Min.: 128

      Max.: 383

      Operates between 9 to 54 pulses
      A/O Servo Pulse(F&R D) Rear mode damper servo sub-assembly pulse

      Min.: 128

      Max.: 383

      Operates between 7 to 83 pulses