GENERATOR REMOVAL

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.

    Click here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. REMOVE FAN SHROUD

    Click here

  4. REMOVE FAN & GENERATOR V BELT

    Click here

  5. REMOVE GENERATOR ASSEMBLY


    1. A0027OA

      Open the terminal cap.

    2. Remove the nut and disconnect the wire harness from terminal B.

    3. Disconnect the generator assembly connector.

    4. Disconnect the magnetic clutch connector.

    5. Disengage the 2 wire harness clamps.

    6. A002B3F

      Type A:


      1. Remove the 2 bolts and generator assembly bracket.

    7. Type B:


      1. A0029OX

        Remove the bolt, nut and generator assembly bracket.

    8. A0027QC

      Remove the 2 bolts and generator assembly.

    9. A002AJP

      Remove the bolt and wire harness clamp bracket.