GENERATOR REMOVAL

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notice before proceeding with work.

    Click here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. REMOVE V-RIBBED BELT

    Click here

  4. REMOVE GENERATOR ASSEMBLY


    1. A00276X

      Open the terminal cap.

    2. Remove the nut and disconnect the wire harness from terminal B.

    3. Disconnect the generator assembly connector.

    4. Remove the bolt and wire harness clamp bracket from the generator assembly.

    5. A002C5H

      Remove the 2 bolts and generator assembly.