NAVIGATION SYSTEM(for Radio and Display Type) Speaker Circuit

DESCRIPTION

for 6 Speakers:

If there is a short in a speaker circuit, the radio and display receiver assembly detects it and stops output to the speakers.

Thus sound cannot be heard from the speakers even if there is no malfunction in the radio and display receiver assembly or speakers.

for 12 Speakers:

If there is a short in a speaker circuit, the stereo component amplifier assembly detects it and stops output to the speakers.

Thus sound cannot be heard from the speakers even if there is no malfunction in the stereo component amplifier assembly or speakers.

WIRING DIAGRAM


  1. for 6 Speakers

    A01QWRLE50
  2. for 12 Speakers

    A01QV8EE02
    A01QVZNE03

PROCEDURE


  1. CONFIRM MODEL


    1. Choose the model to be inspected.

      Result
      Result Proceed to
      for 6 Speakers A
      for 12 Speakers B

    B
    A
  2. CHECK SPEAKER (OPERATION CHECK)


    1. A0028M8

      Enter the "System Check Mode" screen. Refer to Check Speaker in Operation Check.

      Click here

    2. Perform the operation check above and determine the speaker that is not operating.

      Result
      Not Operating Speaker Proceed to
      Front No. 1 speaker assembly or front No. 2 speaker assembly A
      Rear speaker assembly B

      Tech Tips

      If sound cannot be heard from any speaker, inspect all of them.


    B
    A
  3. CHECK HARNESS AND CONNECTOR (RADIO AND DISPLAY RECEIVER ASSEMBLY - FRONT NO. 2 SPEAKER ASSEMBLY - FRONT NO. 1 SPEAKER ASSEMBLY)


    1. Disconnect the F69 radio and display receiver assembly connector.

    2. Disconnect the G1 and G5 front No. 2 speaker assembly connectors.

    3. Disconnect the H3 and I3 front No. 1 speaker assembly connectors.

    4. Measure the resistance between each of the radio and display receiver assembly and the front No. 2 speaker assemblies to check for an open circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F69-1 (FR+) - G1-4 (+) Always Below 1 Ω
      F69-5 (FR-) - G1-2 (-) Always Below 1 Ω
      F69-2 (FL+) - G5-4 (+) Always Below 1 Ω
      F69-6 (FL-) - G5-2 (-) Always Below 1 Ω
    5. Measure the resistance between the front No. 2 speaker assemblies and each of the front No. 1 speaker assemblies to check for an open circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      G1-3 (+) - H3-1 Always Below 1 Ω
      G1-1 (-) - H3-2 Always Below 1 Ω
      G5-3 (+) - I3-1 Always Below 1 Ω
      G5-1 (-) - I3-2 Always Below 1 Ω
    6. Measure the resistance between the radio and display receiver assembly and body ground to check for a short circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F69-1 (FR+) - Body ground Always 10 kΩ or higher
      F69-5 (FR-) - Body ground Always 10 kΩ or higher
      F69-2 (FL+) - Body ground Always 10 kΩ or higher
      F69-6 (FL-) - Body ground Always 10 kΩ or higher
    7. Measure the resistance between each of the front No. 2 speaker assemblies and body ground to check for a short circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      G1-3 (+) - Body ground Always 10 kΩ or higher
      G1-1 (-) - Body ground Always 10 kΩ or higher
      G5-3 (+) - Body ground Always 10 kΩ or higher
      G5-1 (-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. INSPECT FRONT NO. 2 SPEAKER ASSEMBLY


    1. Remove the front No. 2 speaker assembly.

      Click here

    2. A01QWA4C36
      *a

      Component without harness connected

      (Front No. 2 Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (+) - 2 (-) Always 10 kΩ or higher
      3 (+) - 4 (+) Always Below 1 Ω
      1 (-) - 2 (-) Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  5. REPLACE FRONT NO. 2 SPEAKER ASSEMBLY


    1. Check that the malfunction disappears when a known good speaker is installed.

      Click here

      OK
      Malfunction disappears.

      Tech Tips


      • Connect all the connectors to the front No. 2 speaker assemblies that were disconnected.

      • When there is a possibility that either the right or left front No. 2 speaker assembly is defective, inspect by interchanging the right one with the left one.

      • Perform the above inspection on both the LH and RH side.

      Result
      Proceed to
      OK
      NG

    OK
    NG
  6. INSPECT FRONT NO. 1 SPEAKER ASSEMBLY


    1. Remove the front No. 1 speaker assembly.

      Click here

    2. A002CKTC30
      *a

      Component without harness connected

      (Front No. 1 Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 3.2 to 4.8 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG
  7. CHECK HARNESS AND CONNECTOR (RADIO AND DISPLAY RECEIVER ASSEMBLY - REAR SPEAKER ASSEMBLY)


    1. Disconnect the F70 radio and display receiver assembly connector.

    2. Disconnect the J4 and K4 rear speaker assembly connectors.

    3. Measure the resistance between the radio and display receiver assembly and each of the rear speaker assemblies to check for an open circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F70-1 (RR+) - J4-1 Always Below 1 Ω
      F70-3 (RR-) - J4-2 Always Below 1 Ω
      F70-2 (RL+) - K4-1 Always Below 1 Ω
      F70-6 (RL-) - K4-2 Always Below 1 Ω
    4. Measure the resistance between the radio and display receiver assembly and body ground to check for a short circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F70-1 (RR+) - Body ground Always 10 kΩ or higher
      F70-3 (RR-) - Body ground Always 10 kΩ or higher
      F70-2 (RL+) - Body ground Always 10 kΩ or higher
      F70-6 (RL-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  8. INSPECT REAR SPEAKER ASSEMBLY


    1. Remove the rear speaker assembly.

      Click here

    2. A002CKTC30
      *a

      Component without harness connected

      (Rear Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 3.2 to 4.8 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG
  9. CHECK SPEAKER (OPERATION CHECK)


    1. A0028M8

      Enter the "System Check Mode" screen. Refer to Check Speaker in Operation Check.

      Click here

    2. Perform the operation check above and determine the speaker that is not operating.

      Result
      Not Operating Speaker Proceed to
      Front No. 1 speaker assembly A
      Front No. 3 speaker assembly B
      Rear speaker assembly C
      Rear No. 3 speaker assembly D
      Front No. 2 speaker assembly E
      Rear No. 2 speaker assembly F

      Tech Tips

      If sound cannot be heard from any speaker, inspect all of them.


    B
    C
    D
    E
    F
    A
  10. CHECK HARNESS AND CONNECTOR (STEREO COMPONENT AMPLIFIER ASSEMBLY - FRONT NO. 1 SPEAKER ASSEMBLY)


    1. Disconnect the F75 stereo component amplifier assembly connector.

    2. Disconnect the H3 and I3 front No. 1 speaker assembly connectors.

    3. Measure the resistance between the stereo component amplifier assembly and each of the front No. 1 speaker assemblies to check for an open circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F75-15 (FR+) - H3-1 Always Below 1 Ω
      F75-30 (FR-) - H3-2 Always Below 1 Ω
      F75-11 (FL+) - I3-1 Always Below 1 Ω
      F75-26 (FL-) - I3-2 Always Below 1 Ω
    4. Measure the resistance between the stereo component amplifier assembly and body ground to check for a short circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F75-15 (FR+) - Body ground Always 10 kΩ or higher
      F75-30 (FR-) - Body ground Always 10 kΩ or higher
      F75-11 (FL+) - Body ground Always 10 kΩ or higher
      F75-26 (FL-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  11. INSPECT FRONT NO. 1 SPEAKER ASSEMBLY


    1. Remove the front No. 1 speaker assembly.

      Click here

    2. A002CKTC30
      *a

      Component without harness connected

      (Front No. 1 Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 4.6 to 6.6 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG
  12. CHECK HARNESS AND CONNECTOR (STEREO COMPONENT AMPLIFIER ASSEMBLY - FRONT NO. 3 SPEAKER ASSEMBLY)


    1. Disconnect the F75 stereo component amplifier assembly connector.

    2. Disconnect the G3 front No. 3 speaker assembly connector.

    3. Measure the resistance between the stereo component amplifier assembly and the front No. 3 speaker assembly to check for an open circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F75-10 (CTR+) - G3-2 Always Below 1 Ω
      F75-25 (CTR-) - G3-1 Always Below 1 Ω
    4. Measure the resistance between the stereo component amplifier assembly and body ground to check for a short circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F75-10 (CTR+) - Body ground Always 10 kΩ or higher
      F75-25 (CTR-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  13. INSPECT FRONT NO. 3 SPEAKER ASSEMBLY


    1. Remove the front No. 3 speaker assembly.

      Click here

    2. A01QVISC29
      *a

      Component without harness connected

      (Front No. 3 Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 6.8 to 10.2 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG
  14. CHECK HARNESS AND CONNECTOR (STEREO COMPONENT AMPLIFIER ASSEMBLY - REAR SPEAKER ASSEMBLY)


    1. Disconnect the F75 stereo component amplifier assembly connector.

    2. Disconnect the J4 and K4 rear speaker assembly connectors.

    3. Measure the resistance between the stereo component amplifier assembly and each of the rear speaker assemblies to check for an open circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F75-12 (RR+) - J4-1 Always Below 1 Ω
      F75-27 (RR-) - J4-2 Always Below 1 Ω
      F75-4 (RL+) - K4-1 Always Below 1 Ω
      F75-19 (RL-) - K4-2 Always Below 1 Ω
    4. Measure the resistance between the stereo component amplifier assembly and body ground to check for a short circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F75-12 (RR+) - Body ground Always 10 kΩ or higher
      F75-27 (RR-) - Body ground Always 10 kΩ or higher
      F75-4 (RL+) - Body ground Always 10 kΩ or higher
      F75-19 (RL-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  15. INSPECT REAR SPEAKER ASSEMBLY


    1. Remove the rear speaker assembly.

      Click here

    2. A002CKTC30
      *a

      Component without harness connected

      (Rear Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 3.2 to 5.2 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG
  16. CHECK HARNESS AND CONNECTOR (STEREO COMPONENT AMPLIFIER ASSEMBLY - REAR NO. 3 SPEAKER ASSEMBLY)


    1. Disconnect the F75 stereo component amplifier assembly connector.

    2. Disconnect the X23 and X5 rear No. 3 speaker assembly connectors.

    3. Measure the resistance between the stereo component amplifier assembly and each of the rear No. 3 speaker assemblies to check for an open circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F75-9 (SR+) - X23-2 Always Below 1 Ω
      F75-24 (SR-) - X23-1 Always Below 1 Ω
      F75-5 (SL+) - X5-2 Always Below 1 Ω
      F75-20 (SL-) - X5-1 Always Below 1 Ω
    4. Measure the resistance between the stereo component amplifier assembly and body ground to check for a short circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F75-9 (SR+) - Body ground Always 10 kΩ or higher
      F75-24 (SR-) - Body ground Always 10 kΩ or higher
      F75-5 (SL+) - Body ground Always 10 kΩ or higher
      F75-20 (SL-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  17. INSPECT REAR NO. 3 SPEAKER ASSEMBLY


    1. Remove the rear No. 3 speaker assembly.

      Click here

    2. A01QVISC29
      *a

      Component without harness connected

      (Rear No. 3 Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 6.8 to 10.2 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG
  18. CHECK HARNESS AND CONNECTOR (STEREO COMPONENT AMPLIFIER ASSEMBLY - FRONT NO. 2 SPEAKER ASSEMBLY)


    1. Disconnect the F75 stereo component amplifier assembly connector.

    2. Disconnect the G2 and G6 front No. 2 speaker assembly connectors.

    3. Measure the resistance between the stereo component amplifier assembly and each of the front No. 2 speaker assemblies to check for an open circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F75-14 (TWR+) - G2-4 (TWR+) Always Below 1 Ω
      F75-29 (TWR-) - G2-3 (TWR-) Always Below 1 Ω
      F75-13 (TWL+) - G6-4 (TWL+) Always Below 1 Ω
      F75-28 (TWL-) - G6-3 (TWL-) Always Below 1 Ω
    4. Measure the resistance between the stereo component amplifier assembly and body ground to check for a short circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F75-14 (TWR+) - Body ground Always 10 kΩ or higher
      F75-29 (TWR-) - Body ground Always 10 kΩ or higher
      F75-13 (TWL+) - Body ground Always 10 kΩ or higher
      F75-28 (TWL-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  19. INSPECT FRONT NO. 2 SPEAKER ASSEMBLY


    1. Remove the front No. 2 speaker assembly.

      Click here

    2. A01QWA4C38
      *A for RH
      *B for LH
      *a

      Component without harness connected

      (Front No. 2 Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      4 (TWR+) - 3 (TWR-) Always 3.4 to 5.2 Ω
      4 (TWL+) - 3 (TWL-) Always 3.4 to 5.2 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG
  20. CHECK HARNESS AND CONNECTOR (STEREO COMPONENT AMPLIFIER ASSEMBLY - REAR NO. 2 SPEAKER ASSEMBLY)


    1. Disconnect the F75 stereo component amplifier assembly connector.

    2. Disconnect the X26 rear No. 2 speaker assembly connector.

    3. Measure the resistance between the stereo component amplifier assembly and the rear No. 2 speaker assembly to check for an open circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F75-8 (WF1+) - X26-4 (WF1+) Always Below 1 Ω
      F75-23 (WF1-) - X26-3 (WF1-) Always Below 1 Ω
      F75-7 (WF2+) - X26-2 (WF2+) Always Below 1 Ω
      F75-22 (WF2-) - X26-1 (WF2-) Always Below 1 Ω
    4. Measure the resistance between the stereo component amplifier assembly and body ground to check for a short circuit in the wire harness.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F75-8 (WF1+) - Body ground Always 10 kΩ or higher
      F75-23 (WF1-) - Body ground Always 10 kΩ or higher
      F75-7 (WF2+) - Body ground Always 10 kΩ or higher
      F75-22 (WF2-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  21. INSPECT REAR NO. 2 SPEAKER ASSEMBLY


    1. Remove the rear No. 2 speaker assembly.

      Click here

    2. A01QWCCC01
      *a

      Component without harness connected

      (Rear No. 2 Speaker Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (WF2-) - 2 (WF2+) Always 4.8 to 6.8 Ω
      3 (WF1-) - 4 (WF1+) Always 4.8 to 6.8 Ω
      Result
      Proceed to
      OK
      NG

    OK
    NG