AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) DATA LIST / ACTIVE TEST


  1. DATA LIST

    Note

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

    Tech Tips

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Check the value(s) by referring to the table below.


      Body Electrical > Air Conditioner > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Room Temperature Sensor Cooler (room temp. sensor) thermistor

      Min.: -6.50°C (20.30°F)

      Max.: 57.25°C (135.05°F)

      Actual cabin temperature displayed -
      Ambient Temp Sensor Thermistor assembly

      Min.: -23.30°C (-9.94°F)

      Max.: 65.95°C (150.71°F)

      Actual ambient temperature displayed -
      Adjusted Ambient Temp Adjusted ambient temperature

      Min.: -30.80°C (-23.44°F)

      Max.: 50.80°C (123.44°F)

      - -
      Evaporator Fin Thermistor No. 1 cooler thermistor

      Min.: -30.00°C (-22.00°F)

      Max.: 59.60°C (139.28°F)

      Actual evaporator temperature displayed -
      Evaporator Target Temp Evaporator target temperature

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Evaporator target temperature displayed -
      Solar Sensor (D Side) Driver side automatic light control sensor

      Min.: 0

      Max.: 255

      Driver side automatic light control sensor value increases as brightness increases -
      Solar Sensor (P Side) Front passenger side automatic light control sensor

      Min.: 0

      Max.: 255

      Front passenger side automatic light control sensor value increases as brightness increases -
      Engine Coolant Temp Engine coolant temperature sensor

      Min.: 1.30°C (34.34°F)

      Max.: 90.55°C (194.99°F)

      Actual engine coolant temperature displayed -
      Blower Motor Speed Level Blower motor speed level

      Min.: 0

      Max.: 31

      Displayed speed level increases between 0 and 31 as blower motor speed increases -
      Regulator Pressure Sensor Air conditioner tube and accessory assembly

      Min.: -456.6 kPaG

      Max.: 3294.3 kPaG

      Actual refrigerant pressure displayed -
      Regulator Control Current Solenoid valve control current

      Min.: 0 A

      Max.: 0.997 A

      Displayed value changes between 0 A and 0.997 A in accordance with solenoid valve operation -
      Room Temp Sensor (Rear) Cooler (No. 2 room temp. sensor) thermistor

      Min.: -6.50°C (20.30°F)

      Max.: 57.25°C (135.05°F)

      Actual rear cabin temperature displayed -
      Evap Temp Sensor (Rear) Rear evaporator temperature sensor

      Min.: -29.70°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual rear evaporator temperature displayed -
      Blower Motor Level (Rear) Rear blower motor speed level

      Min.: 0

      Max.: 31

      Displayed speed level increases between 0 and 31 as rear blower motor speed increases -
      Air Mix Servo Targ Pulse(D) No. 2 air conditioning radiator damper servo sub-assembly (air mix for driver side)*2 or No. 1 air conditioning radiator damper servo sub-assembly (air mix for driver side)*3 target pulse

      Min.: 128

      Max.: 383

      for LHD


      • MAX COLD: 5 (pulse)

      • MAX HOT: 103 (pulse)

      for RHD


      • MAX COLD: 105 (pulse)

      • MAX HOT: 7 (pulse)

      -
      Air Mix Servo Actual Pulse(D) No. 2 air conditioning radiator damper servo sub-assembly (air mix for driver side)*2 or No. 1 air conditioning radiator damper servo sub-assembly (air mix for driver side)*3 actual pulse

      Min.: 128

      Max.: 383

      for LHD


      • MAX COLD: 5 (pulse)

      • MAX HOT: 103 (pulse)

      for RHD


      • MAX COLD: 105 (pulse)

      • MAX HOT: 7 (pulse)

      -
      Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (air mix for front passenger side)*2 or No. 2 air conditioning radiator damper servo sub-assembly (air mix for front passenger side)*3 target pulse

      Min.: 128

      Max.: 383

      for LHD


      • MAX COLD: 105 (pulse)

      • MAX HOT: 7 (pulse)

      for RHD


      • MAX COLD: 5 (pulse)

      • MAX HOT: 103 (pulse)

      -
      Air Mix Servo Actual Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (air mix for front passenger side)*2 or No. 2 air conditioning radiator damper servo sub-assembly (air mix for front passenger side)*3 actual pulse

      Min.: 128

      Max.: 383

      for LHD


      • MAX COLD: 105 (pulse)

      • MAX HOT: 7 (pulse)

      for RHD


      • MAX COLD: 5 (pulse)

      • MAX HOT: 103 (pulse)

      -
      Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) target pulse

      Min.: 128

      Max.: 383


      • FACE: 8 (pulse)

      • B/L: 30 (pulse)

      • FOOT: 74 (pulse)

      • FOOT/DEF: 80 (pulse)

      • DEF: 97 (pulse)

      -
      Air Outlet Servo Actu Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse

      Min.: 128

      Max.: 383


      • FACE: 8 (pulse)

      • B/L: 30 (pulse)

      • FOOT: 74 (pulse)

      • FOOT/DEF: 80 (pulse)

      • DEF: 97 (pulse)

      -
      Air Inlet Damper Targ Pulse Blower damper servo sub-assembly (air inlet) target pulse

      Min.: 128

      Max.: 383


      • Recirculation: 7 (pulse)

      • Fresh: 28 (pulse)

      -
      Air Inlet Damper Actual Pulse Blower damper servo sub-assembly (air inlet) actual pulse

      Min.: 128

      Max.: 383


      • Recirculation: 7 (pulse)

      • Fresh: 28 (pulse)

      -
      Electric Heater Count Maximum quick heater operation level

      Min.: 0

      Max.: 3

      Maximum possible operation of quick heater displayed *1
      Electric Heater Active Level Actual quick heater operation level

      Min.: 0

      Max.: 3

      Actual operation level of quick heater displayed *1
      Shift Set Temperature Shift set temperature 2C decr, 1C decr, Normal, 1C incr, 2C incr Customized value displayed -
      Air Inlet Mode Air inlet mode Auto or Manual Customized value displayed -
      Compressor Mode Compressor mode Auto or Manual Customized value displayed -
      Evaporator Control Evaporator control Auto or Manual Customized value displayed -
      Add Foot Air in FACE Mode Add foot air in face mode ON or OFF Customized value displayed -
      Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
      Fan speed increment control Fan speed increment control Slow, Normal, Fast Customized value displayed -
      Foot/DEF Auto Mode Foot/defroster auto mode ON or OFF Customized value displayed -
      Foot/DEF Auto Blow Up Foot/defroster auto blower speed increase ON or OFF Customized value displayed -
      Ambient Temperature Shift Ambient temperature shift 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr Customized value displayed -
      Air Mix Servo Targ Pls(F&R D) Rear air mix damper servo sub-assembly target pulse

      Min.: 128

      Max.: 383


      • MAX COLD: 9 (pulse)

      • MAX HOT: 54 (pulse)

      -
      A/M Servo Actual Pulse(F&R D) Rear air mix damper servo sub-assembly actual pulse

      Min.: 128

      Max.: 383


      • MAX COLD: 9 (pulse)

      • MAX HOT: 54 (pulse)

      -
      Air Outlet Servo Pls (F&R D) Rear mode damper servo sub-assembly target pulse

      Min.: 128

      Max.: 383


      • FACE: 83 (pulse)

      • B/L: 38 (pulse)

      • FOOT: 7 (pulse)

      -
      A/O Servo Actual Pulse(F&R D) Rear mode damper servo sub-assembly actual pulse

      Min.: 128

      Max.: 383


      • FACE: 83 (pulse)

      • B/L: 38 (pulse)

      • FOOT: 7 (pulse)

      -
      A/C Cutoff Signal Air conditioning control cutoff signal OFF or ON The ECM sends the air conditioning control cutoff signal displayed -
      Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed -
      Set Temperature (D Side) Driver side set temperature

      Min.: MAX COLD

      Max.: MAX HOT

      Driver side set temperature displayed -
      Set Temperature (P Side) Front passenger side set temperature

      Min.: MAX COLD

      Max.: MAX HOT

      Front passenger side set temperature displayed -
      Set Temperature (Rear) Rear passenger side set temperature

      Min.: MAX COLD

      Max.: MAX HOT

      Rear passenger side set temperature displayed -
      Number of Trouble Codes Number of trouble codes

      Min.: 0

      Max.: 255

      Number of DTCs displayed -

      • *1: w/ PTC Heater

      • *2: for LHD

      • *3: for RHD

  2. ACTIVE TEST

    Tech Tips

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Check the operation by referring to the table below.


      Body Electrical > Air Conditioner > Active Test
      Tester Display Measurement Item Control Range Diagnostic Note
      Blower Motor Blower motor with fan sub-assembly

      Min.: 0

      Max.: 31

      -
      Magnetic Clutch Relay Air conditioning system operation OFF or ON -
      Defogger Relay (Rear) Rear window defogger OFF or ON -
      Deicer Relay (Front) Windshield deicer OFF or ON *2
      Heater Active Level Quick heater assembly

      Min.: 0

      Max.: 3

      *1
      Air Mix Servo Targ Pulse(D) No. 2 air conditioning radiator damper servo sub-assembly (air mix for driver side)*3 or No. 1 air conditioning radiator damper servo sub-assembly (air mix for driver side)*4 pulse

      Min.: 128

      Max.: 383


        for LHD:

      • Operates between 5 to 103 pulses


        for RHD:

      • Operates between 7 to 105 pulses

      Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (air mix for front passenger side)*3 or No. 2 air conditioning radiator damper servo sub-assembly (air mix for front passenger side)*4 pulse

      Min.: 128

      Max.: 383


        for LHD:

      • Operates between 7 to 105 pulses


        for RHD:

      • Operates between 5 to 103 pulses

      Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) pulse

      Min.: 128

      Max.: 383

      Operates between 8 to 97 pulses
      Air Inlet Damper Targ Pulse Blower damper servo sub-assembly (air inlet) pulse

      Min.: 128

      Max.: 383

      Operates between 7 to 28 pulses
      Rear Blower Motor Rear blower motor with fan sub-assembly

      Min.: 0

      Max.: 31

      -
      A/M Servo Pulse(F&R D) Rear air mix damper servo sub-assembly pulse

      Min.: 128

      Max.: 383

      Operates between 9 to 54 pulses
      A/O Servo Pulse(F&R D) Rear mode damper servo sub-assembly pulse

      Min.: 128

      Max.: 383

      Operates between 7 to 83 pulses

      • *1: w/ PTC Heater

      • *2: w/ Windshield Deicer System

      • *3: for LHD

      • *4: for RHD