COMBINATION METER REMOVAL

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.

    Click here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. REMOVE INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY


    1. A002BUQ

      Disengage the 4 clips and 2 guides as shown in the illustration.

    2. A002741

      Disengage the 9 claws and 2 guides and remove the instrument cluster finish panel assembly as shown in the illustration.

  4. REMOVE COMBINATION METER ASSEMBLY


    1. A0027Y0

      Remove the 2 screws.

    2. A00276U

      Disengage the 2 clips as shown in the illustration.

    3. Disconnect the 2 connectors to remove the combination meter assembly.