AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P275612

DTC Code DTC Name
P275612 Torque Converter Clutch Pressure Control Solenoid Control Circuit Short to Battery

DESCRIPTION

The ECM controls the solenoid (SLU) valve using a predetermined current, and performs lock-up and flex lock-up control.

B003Z37C02
*1 Spool Valve *2 Sleeve
*3 Solenoid Coil - -
*a Current *b Hydraulic Pressure
DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P275612 Torque Converter Clutch Pressure Control Solenoid Control Circuit Short to Battery

1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other


  1. Vehicle is being driven

  2. Solenoid (SLU) valve circuit is short to +B

  3. 1 second

  4. 1-trip detection logic


  • Solenoid (SLU) valve

  • Transmission wire

  • Harness and connector

  • ECM

Comes on DTC stored

SAE Code:

P2763

MONITOR DESCRIPTION

When a short to +B in the solenoid (SLU) valve circuit is detected, the ECM will determine that there is a malfunction, illuminate the MIL and store this DTC.

WIRING DIAGRAM

B003ZOAE05
*a Solenoid (SLU) Valve
*b Transmission Wire

CAUTION / NOTICE / HINT

Note

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click here

Tech Tips

After the performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.


  1. Perform the Lock-up Function inspection in Road Test.

    Click here

  2. Check for DTCs again.

    Click here

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE (SOLENOID (SLU) VALVE) - ECM)


    1. Disconnect the C1 ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C1-76 (SLU+) or C1-61 (SLU-) - Other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. REPLACE ECM


    1. Replace the ECM.

      Click here

      Result
      Proceed to
      NEXT

    NEXT
  3. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. Disconnect the C62 transmission wire connector.

    2. Disconnect the C1 ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      C62-5 (SLU+) or C1-76 (SLU+) - Other terminals Always 10 kΩ or higher
      C62-4 (SLU-) or C1-61 (SLU-) - Other terminals Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. INSPECT SOLENOID (SLU) VALVE


    1. B003Z4NC76
      *a

      Component without harness connected

      (Solenoid (SLU) Valve)

      Remove the solenoid (SLU) valve.

      Click here

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Solenoid (SLU) valve connector terminal 1 - terminal 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Connect a positive (+) lead from the battery with a 21 W bulb to terminal 1 and a negative (-) lead to terminal 2 of the solenoid valve connector. Check that the valve moves and makes an operating sound.

      OK
      Valve moves and makes operating sound.
      Result
      Proceed to
      OK
      NG

    OK
    NG