TCM INSTALLATION

PROCEDURE


  1. INSTALL TCM


    1. Temporarily install the TCM to the automatic transaxle assembly with the 2 bolts.

    2. A00280FN01

      Tighten the 2 bolts in the order shown in the illustration.

      Torque:
      11.3 N*m  { 115 kgf*cm, 8 ft.*lbf }
    3. A0028CB

      Connect the TCM connector.

    4. Turn the lock lever to secure the connector.

  2. INSTALL AIR CLEANER CASE SUB-ASSEMBLY

    Click here

  3. INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

    Click here

  4. INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE

    Click here

  5. INSTALL INLET AIR CLEANER ASSEMBLY

    Click here

  6. INSTALL COOL AIR INTAKE DUCT SEAL

    Click here

  7. INSTALL RADIATOR SIDE SEAL RH

    Click here

  8. INSTALL RADIATOR SIDE DEFLECTOR SEAL LH

    Click here

  9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  10. CHECK AUTOMATIC TRANSAXLE SYSTEM

    Note

    If automatic transaxle parts have been replaced, refer to Parts Replacement Compensation Table to determine if any additional operations are necessary.

    Click here