PROCEDURE
INSPECT TRANSMISSION FLOOR SHIFT ASSEMBLY (w/o Smart Entry and Start System)
Tech Tips
If the results of the following inspections are as specified but a malfunction has occurred, replace the transmission floor shift assembly.
Inspect wire harness:
Disconnect the shift lock control ECU connector.
| *a | Front view of wire harness connector (to Shift Lock Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, repair or replace the shift lock control ECU wire harness.
| *a | Front view of wire harness connector (to Shift Lock Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, repair or replace the shift lock control ECU wire harness.
Inspect key interlock solenoid operation signal:
Connect the shift lock control ECU connector.
| *a | Component with harness connected (Shift Lock Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Tech Tips
Do not disconnect the shift lock control ECU connector.
If the result is not as specified, repair or replace the transmission floor shift assembly.
Inspect shift lock solenoid:
Disengage the 3 claws to remove the shift lock control ECU from the transmission floor shift assembly.
Disconnect the shift lock solenoid connector.
| *a | Front view of wire harness connector (to Shift Lock Solenoid) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the transmission floor shift assembly.
If the shift lock does not operate when the power source of the transmission floor shift assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the transmission floor shift assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the transmission floor shift assembly.
If the shift lock does not operate when the power source of the transmission floor shift assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the transmission floor shift assembly.
INSPECT TRANSMISSION FLOOR SHIFT ASSEMBLY (w/ Smart Entry and Start System)
Tech Tips
If the results of the following inspections are as specified but a malfunction has occurred, replace the transmission floor shift assembly.
Inspect wire harness:
Disconnect the shift lock control ECU connector.
| *a | Front view of wire harness connector (to Shift Lock Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, repair or replace the shift lock control ECU wire harness.
| *a | Front view of wire harness connector (to Shift Lock Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, repair or replace the shift lock control ECU wire harness.
Inspect shift lock solenoid:
Disengage the 3 claws to remove the shift lock control ECU from the transmission floor shift assembly.
Disconnect the shift lock solenoid connector.
| *a | Front view of wire harness connector (to Shift Lock Solenoid) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the transmission floor shift assembly.
If the shift lock does not operate when the power source of the transmission floor shift assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the transmission floor shift assembly.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the transmission floor shift assembly.
If the shift lock does not operate when the power source of the transmission floor shift assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the transmission floor shift assembly.
INSPECT TRANSMISSION CONTROL SWITCH
Disconnect the transmission control switch connector.
| *a | Component without harness connected (Transmission Control Switch) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the transmission floor shift assembly.