SHIFT LEVER INSPECTION

PROCEDURE


  1. INSPECT TRANSMISSION FLOOR SHIFT ASSEMBLY (w/o Smart Entry and Start System)

    Tech Tips

    If the results of the following inspections are as specified but a malfunction has occurred, replace the transmission floor shift assembly.


    1. Inspect wire harness:


      1. A002BTH

        Disconnect the shift lock control ECU connector.

      2. A0026ZCC23
        *a

        Front view of wire harness connector

        (to Shift Lock Control ECU)

        Measure the voltage according to the value(s) in the table below.

        Standard Voltage
        Tester Connection Condition Specified Condition
        6 (ACC) - Body ground Ignition switch ACC 11 to 14 V
        Ignition switch off Below 1 V
        4 (STP) - Body ground Brake pedal depressed 11 to 14 V
        Brake pedal released Below 1 V
        8 (IG) - Body ground Ignition switch ON 11 to 14 V
        Ignition switch off Below 1 V

        If the result is not as specified, repair or replace the shift lock control ECU wire harness.

      3. A0026ZCC18
        *a

        Front view of wire harness connector

        (to Shift Lock Control ECU)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Value
        1 (E) - Body ground Always Below 1 Ω

        If the result is not as specified, repair or replace the shift lock control ECU wire harness.

    2. Inspect key interlock solenoid operation signal:


      1. A002CJ4

        Connect the shift lock control ECU connector.

      2. A002CHKC01
        *a

        Component with harness connected

        (Shift Lock Control ECU)

        Measure the voltage according to the value(s) in the table below.

        Standard Voltage
        Tester Connection Condition Specified Condition
        5 (KLS+) - Body ground Ignition switch ACC and shift lever in P Below 1 V
        Ignition switch ACC and shift lever not in P 11 to 14 V

        Tech Tips

        Do not disconnect the shift lock control ECU connector.

        If the result is not as specified, repair or replace the transmission floor shift assembly.

    3. Inspect shift lock solenoid:


      1. A002C7C

        Disengage the 3 claws to remove the shift lock control ECU from the transmission floor shift assembly.

      2. A002ANV

        Disconnect the shift lock solenoid connector.

      3. A002882C17
        *a

        Front view of wire harness connector

        (to Shift Lock Solenoid)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        4 (P) - 3 (E2) Shift lever in P 10 kΩ or higher
        Shift lever not in P Below 1 Ω

        If the result is not as specified, replace the transmission floor shift assembly.

        If the shift lock does not operate when the power source of the transmission floor shift assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the transmission floor shift assembly.

      4. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (SLS+) - 2 (SLS-) Always 112 Ω

        If the result is not as specified, replace the transmission floor shift assembly.

        If the shift lock does not operate when the power source of the transmission floor shift assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the transmission floor shift assembly.

  2. INSPECT TRANSMISSION FLOOR SHIFT ASSEMBLY (w/ Smart Entry and Start System)

    Tech Tips

    If the results of the following inspections are as specified but a malfunction has occurred, replace the transmission floor shift assembly.


    1. Inspect wire harness:


      1. A002BTH

        Disconnect the shift lock control ECU connector.

      2. A002919C01
        *a

        Front view of wire harness connector

        (to Shift Lock Control ECU)

        Measure the voltage according to the value(s) in the table below.

        Standard Voltage
        Tester Connection Condition Specified Condition
        6 (STP) - Body ground Brake pedal depressed 11 to 14 V
        Brake pedal released Below 1 V
        12 (IG) - Body ground Engine switch on (IG) 11 to 14 V
        Engine switch off Below 1 V

        If the result is not as specified, repair or replace the shift lock control ECU wire harness.

      3. A002919C02
        *a

        Front view of wire harness connector

        (to Shift Lock Control ECU)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Value
        3 (E) - Body ground Always Below 1 Ω

        If the result is not as specified, repair or replace the shift lock control ECU wire harness.

    2. Inspect shift lock solenoid:


      1. A002C7C

        Disengage the 3 claws to remove the shift lock control ECU from the transmission floor shift assembly.

      2. A002ANV

        Disconnect the shift lock solenoid connector.

      3. A002882C17
        *a

        Front view of wire harness connector

        (to Shift Lock Solenoid)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        4 (P) - 3 (E2) Shift lever in P 10 kΩ or higher
        Shift lever not in P Below 1 Ω

        If the result is not as specified, replace the transmission floor shift assembly.

        If the shift lock does not operate when the power source of the transmission floor shift assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the transmission floor shift assembly.

      4. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 (SLS+) - 2 (SLS-) Always 112 Ω

        If the result is not as specified, replace the transmission floor shift assembly.

        If the shift lock does not operate when the power source of the transmission floor shift assembly is normal and the resistance between the body ground and the shift lock solenoid is as specified, replace the transmission floor shift assembly.

  3. INSPECT TRANSMISSION CONTROL SWITCH


    1. A002AR3

      Disconnect the transmission control switch connector.

    2. A0026ZCC19
      *a

      Component without harness connected

      (Transmission Control Switch)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 (IG) - 7 (S) Shift lever in S, "+" or "-" Below 1 Ω
      Shift lever not in S, "+" or "-" 10 kΩ or higher
      2 (SFTU) - 5 (E) Shift lever held in "+" Below 1 Ω
      Shift lever not held in "+" 10 kΩ or higher
      1 (SFTD) - 5 (E) Shift lever held in "-" Below 1 Ω
      Shift lever not held in "-" 10 kΩ or higher

      If the result is not as specified, replace the transmission floor shift assembly.