MILLIMETER WAVE RADAR SENSOR INSTALLATION

PROCEDURE


  1. INSTALL MILLIMETER WAVE RADAR SENSOR ASSEMBLY


    1. A018LWAN01

      Engage the 2 guides and install the millimeter wave radar sensor assembly with the 3 bolts.

      Torque:
      5.5 N*m  { 56 kgf*cm, 49 in.*lbf }

      Tech Tips

      Tighten the bolts in the order shown in the illustration.

    2. Engage the clamp.

    3. Connect the connector.

  2. INSTALL RADIATOR GRILLE

    Click here

  3. ADJUST MILLIMETER WAVE RADAR SENSOR

    Click here