| DTC Code | DTC Name |
|---|---|
| P0712 | Transmission Fluid Temperature Sensor "A" Circuit Low Input |
| P0713 | Transmission Fluid Temperature Sensor "A" Circuit High Input |
DESCRIPTION
The Automatic Transmission Fluid (ATF) temperature sensor converts the fluid temperature into a resistance value for use by the ECM.
| *1 | Resistance |
| *2 | Acceptable range |
| *3 | Temperature |
The ECM applies a voltage to the temperature sensor through terminal THO1 of the ECM.
The sensor resistance changes with the ATF temperature. As the temperature becomes higher, the sensor resistance decreases.
One terminal of the sensor is grounded so that the sensor resistance decreases and the voltage goes down as the temperature becomes higher.
The ECM calculates the fluid temperature based on the voltage signal.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P0712 | Transmission Fluid Temperature Sensor "A" Circuit Low Input | ATF temperature sensor resistance is less than 79 Ω for 0.5 sec. or more (1-trip detection logic). |
|
Comes on | DTC stored |
| P0713 | Transmission Fluid Temperature Sensor "A" Circuit High Input | ATF temperature sensor resistance is more than 156 kΩ for 0.5 seconds or more, and either of the following conditions is met (1-trip detection logic):
|
|
Comes on | DTC stored |
MONITOR DESCRIPTION
These DTCs indicate an open or short in the automatic transmission fluid (ATF) temperature sensor circuit. The ATF temperature sensor converts ATF temperature into an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature, and can detect an open or short in the ATF temperature circuit. If the resistance value of the ATF temperature sensor is less than 79 Ω*1 or more than 156 kΩ*2, the ECM interprets this as a fault in the ATF sensor or wiring. The ECM will illuminate the MIL and store a DTC.
*1: 150°C (302°F) or more is indicated regardless of the actual ATF temperature.
*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.
Tech Tips
The ATF temperature can be checked on the GTS display.
WIRING DIAGRAM
| *1 | OIL |
| *2 | ATF Temperature Sensor |
| *3 | Automatic Transaxle |
| *4 | Wiring Harness Connector |
CAUTION / NOTICE / HINT
Tech Tips
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
DATA LIST
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Warm up the engine.
Turn the ignition switch off.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| A/T Oil Temperature 1 | ATF temperature sensor value | Min.: -40°C (-40°F) Max.: 215°C (419°F) |
|
If value is -40°C (-40°F) or 150°C (302°F), ATF temperature sensor circuit is open or short circuited |
| Tester Display |
|---|
| A/T Oil Temperature 1 |
Tech Tips
When DTC P0712 is output and the GTS indicates 150°C (302°F) or more, there is a short circuit.
When DTC P0713 is output and the GTS indicates -40°C (-40°F), there is an open circuit.
Measure the resistance between terminal THO1 (OT) and body ground.
| Temperature Displayed | Malfunction |
|---|---|
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or more | Short circuit |
Tech Tips
If the circuit related to the ATF temperature sensor becomes open, P0713 is stored immediately (in 0.5 seconds). When P0713 is stored, P0711 cannot be detected.
It is not necessary to inspect the circuit when P0711 is stored.
PROCEDURE
CHECK HARNESS AND CONNECTOR (ATF TEMPERATURE SENSOR CIRCUIT)
| *a | Front view of wire harness connector (to ECM) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE ECM Click here |
| NG |
|
CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR)
Disconnect the connector from the wiring harness connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)
| *a | Component without harness connected (Transmission Wire) |
Remove the wiring harness connector from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
If the resistance is out of the specified range with the ATF temperature shown in the table below, the driveability of the vehicle may decrease.
| ATF Temperature | Specified Condition |
|---|---|
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE WIRING HARNESS CONNECTOR Click here |
| NG |
|
REPLACE TRANSMISSION WIRE (ATF TEMPERATURE SENSOR) Click here |