DESCRIPTION
Refer to the system description for DTC P2714.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P2716 | Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) | Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic) |
|
Comes on | DTC stored |
MONITOR DESCRIPTION
When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM will illuminate the MIL and store this DTC.
WIRING DIAGRAM
| *1 | Shift Solenoid Valve SLT |
| *2 | Automatic Transaxle |
| *3 | Wiring Harness Connector |
PROCEDURE
CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SLT CIRCUIT)
| *a | Front view of wire harness connector (to ECM) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE ECM Click here |
| NG |
|
CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR)
Disconnect the connector from the wiring harness connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT TRANSMISSION WIRE (SLT)
| *a | Component without harness connected (Transmission Wire) |
Remove the wiring harness connector from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE WIRING HARNESS CONNECTOR Click here |
| NG |
|
INSPECT SHIFT SOLENOID VALVE SLT
| *1 | Shift Solenoid Valve SLT |
Remove shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.
| OK |
|---|
| Valve moves and makes an operating sound. |
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE TRANSMISSION WIRE Click here |
| NG |
|
REPLACE SHIFT SOLENOID VALVE SLT Click here |