PROCEDURE
INSTALL AIR FUEL RATIO SENSOR (for Bank 1)
| *a | Length of SST 30 mm (1.18 in.) |
| *b | Length of Torque Wrench 260 mm (10.2 in.) |
Using SST, install the air fuel ratio sensor to the exhaust manifold sub-assembly RH.
Note
If the air fuel ratio sensor has been struck or dropped, replace it.
Tech Tips
This torque value is effective when SST is parallel to the torque wrench.
The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).
The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 260 mm (10.2 in.).
If using a torque wrench with a different length, or connecting the torque wrench and SST at an angle, refer to the alternate torque values.
INSTALL EXHAUST MANIFOLD SUB-ASSEMBLY RH
INSTALL MANIFOLD STAY
INSTALL AIR FUEL RATIO SENSOR (for Bank 2)
| *a | Length of SST 30 mm (1.18 in.) |
| *b | Length of Torque Wrench 260 mm (10.2 in.) |
Using SST, install the air fuel ratio sensor to the exhaust manifold sub-assembly LH.
Note
If the air fuel ratio sensor has been struck or dropped, replace it.
Tech Tips
This torque value is effective when SST is parallel to the torque wrench.
The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).
The "with SST" torque value is effective when using a torque wrench with a fulcrum length of 260 mm (10.2 in.).
If using a torque wrench with a different length, or connecting the torque wrench and SST at an angle, refer to the alternate torque values.
Connect the air fuel ratio sensor connector.
Engage the wire harness clamp.
INSPECT FOR EXHAUST GAS LEAK
PERFORM INITIALIZATION
Perform "Inspection After Repair" after replacing the air fuel ratio sensor.